Home Products News Contact Us
Home > Supports > Diesel Engine > 4 Factors Affecting The Operation of Shangchai Diesel Generator Sets

4 Factors Affecting The Operation of Shangchai Diesel Generator Sets

Sep. 28, 2024

Shangchai diesel generator sets have excellent power performance, economy, stability, reliability, operability, and low operation and maintenance costs, and can be applied in many environmental situations. However, users still need to pay special attention to some extreme environments, especially the following four environmental factors that can affect the normal operation of Shangchai diesel generator sets.


genset generator


1. The air contains corrosive chemical gases, which can easily cause corrosion to the unit and lead to unit failure. Top Power requires that the surrounding area of the diesel generator set should be kept clean to avoid the presence of flammable and explosive materials. At the same time, it is also important to take necessary fire-fighting measures.

 

2. If the Shangchai diesel generator set is used by the sea, and there is salt water (fog) at the sea, the stable output power of the unit will also be affected at higher altitudes.

 

3. The environmental conditions of dust or sandstorms also have a certain impact on the operation of machinery.

 

4. Rainwater is damp. Users should fully consider the impact of various complex climates on Shangchai diesel generators to ensure their normal operation.

 

Generally, for different environmental factors, generator manufacturers suggest that users can improve the impact of the environment on diesel generators through the following three points:

 

1. Install anti condensation heater: Used in environments with high humidity and easy condensation in the air. When the diesel generator is not running, turn on the heater to make the body temperature of the diesel generator about 5K higher than the ambient temperature. When running, cut off the power supply to the heater

 

2. IP23 protection level: The standard IP22 is to prevent vertically dripping rainwater from entering the interior of the motor.

 

3. Air filter: In some places, due to strong sandstorms or high levels of dust in the air, installing an air filter can effectively remove impurities from the air, ensuring that the air entering the unit during operation is clean.

 

Most of the Shangchai diesel generator sets provided by the Dingbo series have an IP23 protection level and are equipped with "three filters" (air filter, oil filter, fuel filter) devices, which can meet the operating requirements of most environments.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us