1 Open the hand pump (1), by pressing it in and turning it counter-clockwise. 2 Purge the fuel system by pumping at least 250 strokes on the hand pump. Pump rapidly, to maintain pressure in the pump. NOTICE! Purging is not complete while resistance is felt in the pump. 3 Close the hand pump (1) by pressing it in and turning it clockwise. 4 Start the engine and let it idle for at least 5 minutes, before speed is increased.
The closed circuit breather separator is mounted on the right hand side of the gearcase and is connected to the air inlet system between the air cleaner and turbocharger via the breather valve
Remove the filter separator canister using a strap wrench see Fig. 33 fill the new filter/ separator with clean engine oil to the rubber seal, then screw the canister onto the housing using firm hand pressure.
3 Check that the filter sealing surface is clean. 4 Install a new filter (3) and a new O-ring (2). 5 Install the filter cover (1) and filter. Tightening torque: 40 Nm (29.5 lbf. ft.) 6 Fill with engine oil; refer to Administration page 16. 7 Start the engine and check that there is oil pressure. 8 Check that no leakage is present. 9 Stop the engine and check the oil level after a couple of minutes.