The fan plot only applies to a given air temperature, normally 20 °C (68 °F), which gives an air density of 1.2 kg/m3 (0.075 lb/ft.3). If the plot is not drawn for 20 °C the actual temperature and density must be specified. The pressure from the fan plot must be recalculated for other temperatures. If the fan graph applies to an air density of ρ0 and the actual air density is ρ1, the pressure ρ0 from the graph is recalculated as follows:
Volvo Penta only uses liquid-cooled engines. The cooling system comprises a cooling water system and a cooling air system. The objective of the system is to lead heat from the engine to the surrounding atmosphere. Around 40 % of fuel energy is used to perform mechanical work, while the rest is lost as heat to the coolant and through the exhaust.
Volvo Penta engine sound power levels are measured in a semi echo-free chamber. The ceiling and walls are covered with sound absorbing wedges. The engine is placed on a hard, reflection floor. By using the chamber, sound propagation equivalent to open field conditions is ensured.
Volvo TAD734GE engine DU is an computerized instrument panel which shows engine working values on an LCD screen. In the display it is possible to show multiple windows with different information, i. g. engine rpm, coolant temperature, fuel consumption and fault messages.