Home Products News Contact Us
Home > Supports > Diesel Engine > Maintenance Techniques for Radiator of Diesel Generator Set

Maintenance Techniques for Radiator of Diesel Generator Set

Oct. 09, 2023

Do you know how to maintain the radiator of diesel generator sets? Firstly, in dusty or dirty environments, the gaps in the radiator may be blocked by debris, insects, and other objects, which can affect the efficiency of the radiator. Regular cleaning of these light sediments can be done by using low-pressure hot water and cleaning agents to spray steam or water from the front of the radiator towards the electric fan. Spraying from the opposite direction will only blow dirt into the center. When using this method, a cloth should be used to shield the diesel engine and AC generator. If stubborn deposits cannot be removed using the above methods, the radiator can be removed and immersed in hot alkaline water for about 20 minutes, then rinsed clean with hot water.


diesel generating set


The coolant of the radiator of a diesel generator set in operation is usually very hot and under pressure. It is not allowed to tidy the radiator or remove the pipes before cooling, and do not work on the radiator or open the fan protective cover while the fan is rotating. Corrosion is the primary cause of problems in radiators. Always ensure that the pipe joints do not leak, and regularly add water to discharge air from the top of the radiator to ensure that there is no air in the system. The radiator should not be in a partially filled and drained state, as this will further accelerate corrosion.


Regarding diesel generator sets that do not operate, it is necessary to completely evacuate or fill them with water. If possible, use distilled water or natural soft water and add an appropriate amount of rust inhibitor.


Jiangsu Dingbo Power Generation Equipment Co., Ltd. has been established for many years. In addition to strict requirements on the quality of diesel generator set products and after-sales service, it also has strict regulations on the plant environment, production equipment and supporting facilities, which reflects the strict style of Dingbo people. It is not only responsible for generator products, customers, but also employees, so that every employee of Dingbo Power generation equipment can work in a comfortable environment, Make it comfortable for every visiting customer to visit. Dingbo Power Group, relying on high-quality generators, generator sets, diesel generator, diesel generator sets, good services and the care of friends from all walks of life, carries forward the enterprise spirit of "pragmatic innovation, pioneering, unity and hard work, dare to be the first", and adheres to the enterprise style of "treating people with sincerity and heart to heart", has won the strong support of customers in the fields of post and telecommunications, finance, petrochemical, metallurgy, transportation, education, medical care, etc, Having a proud performance. Dingbo people are gradually moving towards economies of scale and entering the international market after joining the WTO with flexible sales strategies and relying on the company's advantages and strength. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us