Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. is an OEM authorized manufacturer for the main engine supporting of Yuchai diesel generator sets. We have 800KW Yuchai diesel generator sets in stock. The whole set of products is well-made, reasonably priced, and has a low fuel consumption rate. The 800KW Yuchai generator set is equipped with the Yuchai YC6C1320-D31 engine. The YC6C series engines are the result of digesting and absorbing the consulting achievements of an internationally top-notch engine design company. It is a highly competitive new generation of power generation power, with the advantages of energy conservation, environmental protection, excellent performance, and compact structure. The power, economy, and reliability indicators have reached the international advanced level, and it is a professional supporting power for 600 - 1000kW generator sets.
The technical parameters of the YC6C1320-D31 diesel engine of the Yuchai generator set are as follows:
Model: YC6C1320-D31
Type: Vertical, in-line, water-cooled, four-stroke
Intake method: Exhaust gas turbocharging, intercooled
Combustion chamber form: Direct injection re-entrant ω combustion chamber
Number of cylinders: 6
Number of valves per cylinder: 4
Cylinder diameter: 200mm
Piston stroke: 210mm
Total piston displacement (L): 39.584
Compression ratio: 14.5:1
Cylinder type: Wet cylinder liner
Fuel supply system: Electronic control unit pump
Lubrication method: Pressure and splash combined
Starting method: Electric starting
Oil capacity: 150 - 180L
Crankshaft rotation direction: Counterclockwise (facing the power output end)
Rated fuel consumption rate g/(kW•h): ≤220
Oil consumption rate g/(kW•h): ≤0.5
Minimum no-load speed (r/min): 600 - 650
Fuel grade:
·Summer: Grade A or Class I 0# or 5# ordinary diesel according to GB 252 - 2011.
·Winter: Grade A or Class I 0#, -10#, -20#, -35# light ordinary diesel according to GB 252 - 2011 (selected according to ambient temperature).
Oil grade:
Summer: 15W - 40 CH-4
Winter: 5W - 30 CH-4, 10W - 30 CH-4, 15W - 30
Noise limit Lw dB(A): ≤122
Emission standard: Non-road Stage III (T3)
Net weight: 4700kg
Overall dimensions (length × width × height): 2980 × 1422 × 2095 mm
Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences