Home Products News Contact Us
Home > Supports > Diesel Engine > The Difference Between Backup Generators and Portable Generators

The Difference Between Backup Generators and Portable Generators

Apr. 23, 2024

Portable generators and backup generators are significantly different. A clear difference lies in their names; Portable generators can be carried with you to any place that requires electricity, whether it's camping or work. On the other hand, backup generators are designed to be located in one place, without any handles or wheels to move them, but connected to the house's electrical circuit through related circuits.


power generator manufacturers


Portable generators will be very small and will have a small engine that can provide power for a short period of time, which is only suitable for essential items to operate during power outages. The backup generator is designed for long-term power supply and can supply power to almost all household appliances.

 

Another difference is that when you need power, you must manually turn on and off the portable generator, and regularly check them for any malfunctions that require regular maintenance to ensure a long lifespan. However, if we talk about backup generators, then because they are always connected to the house's electrical circuit, they feel the power condition on the utility lines. If there is a power outage, the backup generator will automatically start, and when it returns, the generator will automatically shut down.

 

In addition, automatic generators perform automatic testing on them and notify users if there are any issues with the system, so there is no need for manual inspection.

 

When it comes to portable generators, they need to operate outdoors. If used indoors, the exhaust gases emitted by these generators accumulate and can be fatal if inhaled. If they are outside, there is a risk of theft. But for backup generators, due to their heavy weight, they are not very attractive to thieves.

 

In addition, if you want to run a portable generator as a backup, you must first accumulate fuel, which often evaporates. This does not always provide fresh fuel. For backup generators, they can be directly connected to existing propane or natural gas supplies in your house, and they will be ready at any time when you want them to work. Dingbo Power provides you with various specifications of diesel generators, such as 30kw-3000k protection, automatic switching and three remote monitoring, low noise and mobile, automatic grid connection systems, etc.

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us