Why Does The Mobile Trailer Diesel Generator Shut Down Frequently?

Nov. 15, 2024

Assuming you find yourself needing electricity during outdoor activities, fieldwork, or unexpected power outages. In this case, you can experience the reliability of the mobile trailer diesel generator. However, if the generator keeps shutting down repeatedly, it may make stable electricity a headache.


commercial diesel generators


In this article, we will explain the common reasons for the continuous shutdown of mobile trailer diesel generators and explore practical solutions to maintain power flow when you need it most.

 

A mobile trailer diesel generator is an independent power unit that can be moved and deployed where electricity is needed. Unlike fixed generators that are typically hard wired to building power systems, mobile trailer diesel generators provide flexibility and mobility. They come in various sizes, from compact ones suitable for outdoor use to large devices capable of supplying power to basic appliances during prolonged power outages.

 

Common reasons why mobile trailer diesel generators may unexpectedly shut down

 

The generator is crucial for providing backup power, but unexpected shutdowns may be a common issue. Here are several reasons why the generator may unexpectedly shut down:

 

Overload: Connecting too many appliances or devices may exceed the capacity of the generator, resulting in automatic shutdown.

 

Low oil level: The generator has a safety function to prevent damage to the engine due to insufficient lubrication, which can lead to automatic shutdown.

 

Dirty air filter: Blockage of the air filter can limit airflow, causing overheating and automatic shutdown for protection.

 

Fuel issues: Expired fuel, carburetor problems, or insufficient fuel supply may damage the fuel air mixture and cause shutdown.

 

Spark plug issue: Worn or dirty spark plugs may cause ignition problems and intermittent shutdowns.

 

Automatic Voltage Regulator (AVR) Failure: AVR issues may cause unstable power output, triggering shutdown.

 

Engine overheating: Insufficient ventilation or high ambient temperature may cause the engine to overheat and automatically shut down.

 

Defects in ignition system: Defects in ignition components may disrupt the start-up and operation of the generator, leading to shutdown.

 

Outdated firmware or software: Lack of software updates may lead to malfunctions and operational issues, resulting in unexpected shutdown of the generator.

 

Mechanical wear: Aging or worn parts may cause frequent and unexpected shutdowns of the generator.

 

Understanding these potential issues can help users perform regular maintenance and troubleshooting to keep the generator running smoothly.

 

Solution for Unexpected Shutdown of Generator

 

If you find that your generator keeps shutting down unexpectedly, please follow the steps below to troubleshoot and solve the problem.

 

Verify oil level: Ensure that your generator has sufficient oil supply??. Low oil level may trigger automatic shutdown.

 

Check the air filter: A clogged air filter can restrict airflow and may cause overheating and shutdown. Regularly clean or replace the air filter.

 

Check the fuel filter: Dirty or clogged fuel filters can hinder fuel flow and cause shutdown. Check and replace the fuel filter as needed.

 

Check spark plugs: Worn or dirty spark plugs may disrupt ignition and cause intermittent shutdowns. Regularly inspect and replace spark plugs.

 

Assessing fuel quality: Outdated or contaminated fuel can affect the performance of the generator. Ensure that you use fresh and clean fuel for optimal operation.

 

Manage load: Generator overload may cause automatic shutdown. Prioritize necessary electrical appliances and reduce loads to prevent overloading.

 

Check for loose connections: Loose electrical connections may cause power outages. Regularly check and tighten all electrical connections.

 

Cleaning the carburetor: A clogged carburetor can damage the fuel air mixture. Regularly clean the carburetor to ensure normal operation.

 

Check the automatic shutdown system: Some generators are equipped with automatic shutdown systems triggered by various issues. Investigate and resolve any malfunctions in the system.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Contact Us
  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us