1.Yuchai engine YC16VC series for diesel generator sets
Yc16vc series engine is a high-power V-type product independently developed by Yuchai. It has the advantages of compact structure, excellent performance, energy conservation and environmental protection, reliability and durability, etc., and the emission pollutants, power, economy and reliability indexes have reached the international advanced level.
Feature
a.The engine body is made of high-strength material, arc stiffener grid structure, four bolt main bearing structure, with high rigidity, small vibration and low noise.
b.The crankshaft is made of high-quality alloy steel with all fiber extrusion forging, shaft diameter and fillet quenching heat treatment, anti-wear and long service life.
c.It adopts electronic control single pump, four valve, high efficiency supercharging and intercooling, Yuchai combustion chamber technology, with low fuel consumption, less emissions, excellent speed regulation performance, fast and powerful loading.
d.One cylinder and one cover structure, the side of the machine body is provided with a maintenance window, which is convenient for maintenance.
e.With world-class equipment and production technology, the quality is stable and reliable.
f.Meet the requirements of G3 level of generator set performance.
Main technical specifications
Item | Technical specifications | ||
Model | YC16VC3000-D31 | YC16VC3300-D31 | YC16VC3600-D31 |
Type | Vertical, In-line, water-cooled, four stroke | ||
Air intake mode | Turbocharged & Intercooled | ||
Cylinder Bore*Stroke | 16 200×210mm | ||
Displacement(L) | 105.56 | ||
Compression ratio | 13.5:1 | ||
Prime power/ speed | 2005kw/1500rpm | 2205kw/1500rpm | 2405kw/1500rpm |
Standby power/ Speed | 2206kw/1500rpm | 2426kw/1500rpm | 2646kw/1500rpm |
Min. Fuel consumption | ≤195g/(kW·h) | ||
Engine oil capacity | 430L | ||
Engine fuel ratio | ≤0.3% | ||
Start mode | Electric start | ||
Fuel system | Electronically-control high pressure common rail | ||
Noise level | ≤106dB(A) | ||
Emission | ECE R96 Stage III A, GB 20891-2014 Stage III | ||
Engine overall size | 3723×1727×2366mm (not including water tank) | ||
Weight | 11400kg (not including water tank radiator) |
2.Yuchai engine YC4R series for diesel generator sets
Based on the power of land use generator set, Raywin Power Train Technology Co.,Ltd together with Yuchai Machinery Co.,Ltd. jointly develop a compact engine for generator set and ship.
Feature
a.Reliable structure, tunnel cylinder block, no cylinder liner structure, high strength, wide adaptability, integrated part design, full simulation analysis.
b.Electric control VP pump, precise control of injection quantity, low fuel consumption, good power, fast transient response;
c.Compact structure and light weight.
d.One side maintenance, three filter and drain plug are on the same side, easy to maintain.
Main technical specifications
Item | Technical specifications | ||||||
Model | 4D24G6 | 4D24G7 | 4D24TG2 | 4D24TG0 | 4D24G3 | 4D24G1 | 4D24TG7 |
Type | Vertical, In-line, water-cooled, four stroke | ||||||
Air intake mode | Naturally aspirated | Turbocharged | Naturally aspirated | Turbocharged | |||
Cylinder Bore*Stroke | 4 87×103mm | ||||||
Displacement(L) | 2.45 | ||||||
Compression ratio | 17.8:1 | ||||||
Frequency/Speed | 50Hz/1500rpm | ||||||
Prime power/ speed | 18.5kw | 23kw | 28kw | 36kw | 22kw | 27kw | 32kw |
Standby power/ Speed | 20.35kw | 25.3kw | 30.8kw | 39.6kw | 24.2kw | 29.7kw | 35.2kw |
Min. Fuel consumption | ≤100/(kW·h) | ||||||
Engine oil capacity | 10L | ||||||
Engine fuel ratio | ≤0.1% | ||||||
Start mode | Electric start | ||||||
Fuel system | Electronically-control VP pump | ||||||
Noise level | ≤92(A) | ||||||
Emission | ECE R96 Stage III A, GB 20891-2014 Stage III | ||||||
Engine overall size | 982×524×804mm (including water tank) | 996×524×804mm (including water tank) |