Home Products News Contact Us
Home > Supports > Diesel Generators > 1000KW Perkins with Ingrid Diesel Generator Set 4012-46TWG2A

1000KW Perkins with Ingrid Diesel Generator Set 4012-46TWG2A

Dec. 21, 2023

The 1000KW Perkins Engel diesel generator set must be a brand new complete set of products, including diesel engines, generators, cooling fans and water radiators, starting, charging, and control screens installed on the same rack as a complete set of equipment; Equipped with a multi-level vibration reduction system, it effectively eliminates the vibration during the operation of the unit, providing better protection for the control system and electrical components.


diesel generator maintenance


The main technical indicators of the diesel generator are as follows:

1) Unit power: 1000KW, with an annual operating time of no less than 500 hours.

2) Rated voltage: 400/230V

3) Rated frequency: 50Hz

4) Power supply method: AC three-phase four wire system

5) Power factor: 0.8 lagging

6) Time required to start to full load ≤ 30 seconds

7) Voltage adjustment rate: steady-state: ≤ ± 1%; Transient:+20% to -20%

8) Frequency adjustment rate: steady-state: ≤ 1%; Transient:+15% to -10%

9) Voltage fluctuation rate: ≤ 0.5% Frequency fluctuation rate: ≤ 0.5%

10) Voltage stability time: ≤ 3S

11) Frequency stability time: ≤ 5S

13) Unit size ≤ 4520 × one thousand nine hundred and twenty × 2500 (length * width * height)

14) Total weight of the unit ≤ 8500KG


The engine of the 1000KW Perkins generator set is the 4012-46TWG2A diesel engine produced by Perkins Engine Limited in the UK. Its main technical indicators are as follows:

1) Electric tuning engine.

2) Power: 1160KW/1055KW ≥ 1100KW,

3) Speed regulation method: electric regulation

4) Starting method: DC24V electric

5) Engine displacement: 45.84L

6) Number of cylinders/arrangement: 12/V

7) Compression ratio 13.6:1

8) Main power load factor: 70%

9) Full load fuel consumption rate (at 100% load): 211g/KWh.

10) Electronic management system: The control system of the engine adopts a computer digital control mode, with an electronic management system and self diagnosis function for faults

11) High pressure oil pump oil supply method: using a single pump and electronic valve control form.

12) The engine overhaul time exceeds 20000 hours.

13) Type: Four stroke, intercooled

14) Rated speed: 1500rpm

15) Cooling method: Fan water tank cooling

16) Air intake method: The engine intake method is forced intake by the turbocharger

17) It is necessary to equip the original factory equipped water tank of the diesel engine. The standard temperature is 50 ℃.


The motor is an EG400-1000N generator produced by Guangzhou Yingge Generator Co., Ltd. The main technical indicators are as follows:

1) The generator is a brushless excitation generator.

2) Rated power: 1000KW

3) Efficiency: 95.37% (provide original factory data)

4) Insulation level: H-level

5) Protection level: IP21

6) Rated frequency: 50Hz

7) Rated power factor: 0.8 (lagging)

8) Excitation system: Brushless excitation

9) Voltage regulation: AVR regulation

10) Phase number: three-phase four wire system

11) Waveform distortion rate: ≤ 5%

12) Short circuit current capability: The short circuit maintenance capability of 300% rated current can reach 5 seconds

13) The telephone influence factor (TIF) is less than 50, and the electromagnetic influence factor (THF) is less than 3%.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Contact Us +

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us