Home Products News Contact Us
Home > Supports > Diesel Generators > 1100kw Cummins Diesel Generator Set K7A50-G2X Technical Parameter Model

1100kw Cummins Diesel Generator Set K7A50-G2X Technical Parameter Model

Mar. 17, 2025

According to the function classification of mechanical equipment, diesel generators belong to electrical and electronic equipment. Cummins diesel generator sets are complete sets of mechanical equipment that convert other forms of energy into electrical energy. They consist of a power system, a control system, a silencing system, a shock absorption system, and an exhaust system. Driven by a diesel engine, they convert the energy generated by fuel combustion or nuclear fission into mechanical energy and transmit it to the generator, which then converts it into electrical energy and outputs it for use by electrical equipment. The 1100kW Cummins diesel generator is assembled by Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. using a Chongqing Cummins K7A50-G2X engine and a brushless all-copper self-excited generator. It has the advantages of excellent starting performance, stable voltage, reliable operation, low emissions, low noise, and convenient maintenance.


Cummins 1100 kw generator


Cummins engines can operate under the following conditions without power adjustment:

For engines with a speed of 1800 r/min, the altitude is below 1500 m (5000 ft) and the ambient temperature is below 40 °C (104 °F).

For engines with a speed of 1500 r/min, the altitude is below 1500 m (5000 ft) and the ambient temperature is below 40 °C (104 °F).

When the engine operates beyond the above conditions, when the altitude is higher than 1500 m (5000 ft), for every 300 m (1000 ft) increase, the power is reduced by 4%; when the ambient temperature is higher than 40 °C (104 °F), for every 11 °C increase, the power is reduced by 2% (for every 10 °F increase, the power is reduced by 1%).

 

Rated operating environment of the 1100KW Cummins generator set:

·Ambient temperature: ≤ 40 °C

·Relative humidity: ≤ 60%

·Altitude: ≤ 1000 m

·Meeting the requirements of ISO3046 and ISO8528.

Optional configurations of the 1100KW Cummins generator set:

·ATS automatic load transfer cabinet

·Automatic paralleling and synchronization cabinet

·Containerized generator set

·Mobile trailer power station

·Rainproof cover type generator set

·Silent mobile power station

·Remote microcomputer interface

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us