Part 1. Shangchai Diesel Engine Parameters


POWER RATING


Engine Speed

Type of Operation

Engine Power

rpm

kW

Ps

1500

Prime Power

236

320

Stanby Power

260

354


1. Standard & certificate: 

GB/T2820

GB/T1147.1

ISO/TS16949:2002 Quality Management System

ISO14001 Environment Management System

OHSAS18001 Occupation Health and Safety Management System

LL-C Certificate

2. Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating.

3. Standby power is available in the even of a utility power outage or under test conditions for up to 200 hours of operation per year. The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating.

 

SPECIFICATIONS

FUEL CONSUMPTION

Engine Model

SC13G355D2

Power

lit/hr

Engine Type

In-line, 4 strokes, water-cooled, 4 valves, Turbo charged air-to-air intercooled

25%

15.8



50%

31.6

Combustion type

Direction injection

75%

47.1

Cylinder Type

Wet liner

100%

65.2

Number of cylinders

6

110%

72.8

Bore × stroke

135(5.32) × 150(5.9) mm(in.)



Displacement

12.88 (786) lit.(in3)



Compression ratio

16 : 1



Firing order

1-5-3-6-2-4

FUEL SYSTEM


Injection timing

15°BTDC

Injection pump

Yijie in-line "P" type

Dry weight

Approx.1296kg (2857.2b)

Governor

Electric type

Dimension

1704×1063×1540mm

Feed pump

Mechanical type

  (L×W×H)

(62.2×30.7×50.8 in.)

Injection nozzle

Multi hole type

Rotation

Counter clockwise viewed from Flywheel

Opening pressure

240 kg/cm2 (3414 psi)

Fly wheel housing

SAE NO.1

Fuel filter

Full flow, cartridge type

Fly wheel

SAE NO. 14

Used fuel

Diesel fuel oil





MECHANISM

LUBRICATION SYSTEM

Type

Over head valve

Lub. Method

Fully forced pressure feed type

Number of valve

Intake 1, exhaust 1 per cylinder

Oil pump

Gear type driven by crankshaft

Valve lashes at cold

Intake 0.325mm (0.0128 in.)

Oil filter

Full flow, cartridge type


Exhaust 0.375mm (0.0148 in.)

Oil pan capacity

High level 41 liters ( 10.82 gal.)

Low level 33 liters (8.71 gal)



Angularity limit

Front down 25 deg.

Front up 35 deg.

Side to side 35 deg.

VALVE TIMING


Opening        

Close

Intake valve

20°BTDC

48°ABDC



Exhaust valve

48°BBDC

20°ATDC

Lub. Oil

Refer to Operation Manual





COOLING SYSTEM

ENGINEERING DATA

Cooling method

Fresh water forced circulation

Water flow

450 liters/min @1,500 rpm

Water capacity (engine only)

25.5 liters ( 6.73 gal.)

Heat rejection to coolant

33.8 kcal/sec @1,500 rpm



Heat rejection to CAC20.7 m3/min @1,500 rpm

Pressure system

Max. 0.5 kg/cm2 ( 7.11 psi)

Air flow

19.5 m3/min @1,500 rpm

Water pump

Centrifugal type driven by belt

Exhaust gas flow

50.3 m3/min @1,500 rpm

Water pump Capacity

450 liters( 118.8 gal.)/min at 1, 500 rpm(engine)

Exhaust gas temp.

600 °C @1,500 rpm

Thermostat

Wax-pellet type

Opening temp. 77°C

Full open temp. 90°C

Max. permissible restrictions


Intake system

3 kPa initial

6 kPa final

Cooling fan

Blower type, plastic

920 mm diameter, 6 blades

Exhaust system

6 kPa max

Max. permissible altitude

2,000 m





ELECTRICAL SYSTEM

CONVERSION TABLE

Charging generator

28V×55A

in. = mm × 0.0394

lb/ft = N.m × 0.737

Voltage regulator

Built-in type IC regulator

PS = kW × 1.3596

U.S. gal = lit. × 0.264

Starting motor

24V×7.5kW

psi = kg/cm2 × 14.2233

kW = 0.2388 kcal/s

Battery Voltage

24V

in3 = lit. × 61.02

lb/PS.h = g/kW.h × 0.00162

Battery Capacity

180 AH

hp = PS × 0.98635

cfm = m3/min × 35.336



lb = kg × 2.20462



Shangchai diesel engine.jpg


Alternators we can supply original Stamford, Siemens, Leroy-somer, Marathon, Engga, and our own brand Starlight alternator. 


Starlight ENGGA generator EG Series uniaxial and biaxial brushless AC generators are designed by Guangzhou Engga Generator Co.,Ltd. Power ranging is from 40KW to 3000KW; frequency is 50Hz/60Hz.


Part 2. ENGGA alternator basic data is given below:


Alternator Data

Output Power (KW)

220KW

Structure

One-piece

Excitation type

Brushless Self Excitation

Overload Capacity

10% overload for one hour

Insulation Class

H

Short-time Current

150%10S

Protection Class

IP22

Mode of Connection

3-phase, 4-line, neutral ground

Rated Voltage

400V

Power Factor

0.8Lag

Rated Frequency50 HzRated Speed1500rpm


ENGGA generator.jpg

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us