1. 200KW 250KVA Shangchai diesel generator SC9D340D2 engine technical parameters is given below:


POWER RATING


Engine Speed

Type of Operation

Engine Power

rpm

kW

Ps

1500

Prime Power

228

310

Stanby Power

250

340


1. Standard & certificate: 

GB/T2820

GB/T1147.1

ISO/TS16949:2002 Quality Management System

ISO14001 Environment Management System

OHSAS18001 Occupation Health and Safety Management System

LL-C Certificate

2. Prime power is available for an unlimited number of hours per year in a variable load application. The permissible average power output over 24 hours of operation shall not exceed 80% of the prime power rating.

3. Standby power is available in the even of a utility power outage or under test conditions for up to 200 hours of operation per year. The permissible average power output over 24 hours of operation shall not exceed 80% of the standby power rating.

 

SPECIFICATIONS

FUEL CONSUMPTION

Engine Model

SC9D340D2

Power

lit/hr

Engine Type

In-line, 4 strokes, water-cooled, 4 valves, Turbo charged air-to-air intercooled

25%

14.7



50%

27.3

Combustion type

Direction injection

75%

40.8

Cylinder Type

Wet liner

100%

54.1

Number of cylinders

6

110%

59.6

Bore × stroke

114(4.49) × 144(5.67) mm(in.)



Displacement

8.82 (538.2) lit.(in3)



Compression ratio

16.5 : 1



Firing order

1-5-3-6-2-4

FUEL SYSTEM


Injection timing

8.5°BTDC

Injection pump

Longkou in-line "P" type

Dry weight

Approx.840kg (1852b)

Governor

Electric type

Dimension

1578×778×1290mm

Feed pump

Mechanical type

  (L×W×H)

(62.2×30.7×50.8 in.)

Injection nozzle

Multi hole type

Rotation

Counter clockwise viewed from Flywheel

Opening pressure

250 kg/cm2 (3556 psi)

Fly wheel housing

SAE NO.2

Fuel filter

Full flow, cartridge type

Fly wheel

SAE NO. 11.5

Used fuel

Diesel fuel oil





MECHANISM

LUBRICATION SYSTEM

Type

Over head valve

Lub. Method

Fully forced pressure feed type

Number of valve

Intake 2, exhaust 2 per cylinder

Oil pump

Gear type driven by crankshaft

Valve lashes at cold

Intake 0.30mm (0.0118 in.)

Oil filter

Full flow, cartridge type


Exhaust 0.55mm (0.0217 in.)

Oil pan capacity

High level 25 liters ( 6.6 gal.)

Low level 22 liters (5.8 gal)



Angularity limit

Front down 25 deg.

Front up 35 deg.

Side to side 35 deg.

VALVE TIMING


Opening        

Close

Intake valve

29.5°BTDC

42.5°ABDC



Exhaust valve

69.5°BBDC

34.5°ATDC

Lub. Oil

Refer to Operation Manual





COOLING SYSTEM

ENGINEERING DATA

Cooling method

Fresh water forced circulation

Water flow

200 liters/min @1,500 rpm

Water capacity (engine only)

12 liters ( 3.17 gal.)

Heat rejection to coolant

20.35kcal/sec @1,500 rpm



Heat rejection to CAC10.2 m3/min @1,500 rpm

Pressure system

Max. 0.5 kg/cm2 ( 7.11 psi)

Air flow

18.6 m3/min @1,500 rpm

Water pump

Centrifugal type driven by belt

Exhaust gas flow

41 m3/min @1,500 rpm

Water pump Capacity

200 liters( 52.8 gal.)/min at 1, 500 rpm(engine)

Exhaust gas temp.

600 °C @1,500 rpm

Thermostat

Wax-pellet type

Opening temp. 82°C

Full open temp. 93°C

Max. permissible restrictions


Intake system

3 kPa initial

6 kPa final

Cooling fan

Blower type, plastic

762 mm diameter, 10 blades

Exhaust system

6 kPa max

Max. permissible altitude

2,000 m





ELECTRICAL SYSTEM

CONVERSION TABLE

Charging generator

28V×55A

in. = mm × 0.0394

lb/ft = N.m × 0.737

Voltage regulator

Built-in type IC regulator

PS = kW × 1.3596

U.S. gal = lit. × 0.264

Starting motor

24V×7.5kW

psi = kg/cm2 × 14.2233

kW = 0.2388 kcal/s

Battery Voltage

24V

in3 = lit. × 61.02

lb/PS.h = g/kW.h × 0.00162

Battery Capacity

180 AH

hp = PS × 0.98635

cfm = m3/min × 35.336



lb = kg × 2.20462



Shangchai engine SC9D340D2.jpg


Note: As one of leading manufacturers of diesel generator in China, we can provide 50KW to 1600KW diesel generating sets with Shangchai engine. The genset style includes open generator, soundproof generator, trailer generator, portable generator and containerized genset, etc. The unit can be equipped with ATS and base fuel tank. Alternators we can supply original Stamford, Siemens, Leroy-somer, Marathon, Engga, and our own brand Starlight alternator. 


Alternator basic data is given below:



Alternator Data

Output Power (KW)

200KW

Structure

One-piece

Excitation type

Brushless Self Excitation

Overload Capacity

10% overload for one hour

Insulation Class

H

Short-time Current

150%10S

Protection Class

IP22

Mode of Connection

3-phase, 4-line, neutral ground

Rated Voltage

400V

Power Factor

0.8Lag

Rated Frequency50 HzRated Speed1500rpm


Note: Control Module you can select Deep Sea (UK) - DSE7320 or SmartGen (China) - HGM6110


DSE7320 control module

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us