Home Products News Contact Us
Home > Supports > Diesel Generators > Cracks on Cylinder Block and Cylinder Head of Diesel Generator Set

Cracks on Cylinder Block and Cylinder Head of Diesel Generator Set

May. 26, 2023

Epoxy resin bonding method and screw filling method for cylinder block and cylinder head of Perkins diesel generator set, and sealing method for cylinder block and cylinder head of Perkins diesel generator set. If the crack is long or there are holes in the parts of the cylinder block and cylinder head of the Perkins diesel generator set where the stress is small, use reinforcing plates around the damaged parts of the Perkins diesel generator set.


perkins generator set


Drill holes at the end of each crack of Perkins diesel generator set to limit the extension of the crack. Cut 3-5mm thick copper plate or 1.5-2mm thick iron plate into patches similar to the fracture contour, and the area around the fracture is greater than 15-20mm. If there is a bulge on the disconnected surface of Perkins diesel generator set, the bulge of the same shape shall be knocked out on the terminal block, so that the whole terminal block of Perkins diesel generator set can match the surface of the wiring part.


Press the filler plate on the notch, and use the needle drawn from the filler plate hole to mark the hole on the cylinder block of Perkins diesel generator set. Remove the Perkins diesel generator set filler plate, then drill a hole about 10mm deep on the mark and tap the thread with the required diameter. The asbestos bushing coated with white paint shall be filled between the cylinder block of Perkins diesel generator set and the repair plate, and then the repair plate shall be fixed to the cylinder block of Perkins diesel generator set with flat head bolts. If necessary, the repair plate shall be knocked with a hammer, and the bolts of Perkins diesel generator set shall be further tightened to increase the sealing.


Founded in 1974, Starlight Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Starlight quality is worth depending on. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us