Home Products News Contact Us
Home > Supports > Diesel Generators > How to Efficiently Discharge Diesel from Industrial Generators?

How to Efficiently Discharge Diesel from Industrial Generators?

Nov. 14, 2024

Discharging diesel from industrial diesel generators is a maintenance practice with many benefits. The main reason is to prevent fuel degradation. Over time, diesel undergoes chemical changes, forming varnish and gum deposits, which can damage the integrity of the fuel system. By regularly discharging diesel, the risk of these deposits clogging important components such as carburetors and injectors can be reduced.


75kw diesel generator


In addition, stagnant fuel poses a significant threat to the diesel engine itself. Using outdated fuel may cause start-up issues, and in severe cases, it can lead to permanent damage to the engine. Discharging diesel can ensure that only fresh and high-quality fuel is provided, thereby promoting smoother starting and reducing the possibility of engine related problems.

 

This approach becomes important during periods when the generator is not in operation. When stored for a long time, the generator is prone to fuel decomposition, leading to the formation of gum and overall low fuel efficiency. Discharging diesel before storage can prevent these issues and ensure that the generator remains in optimal condition for the next use.

 

Improve efficiency

 

In addition to these considerations, discharging diesel also helps improve the overall efficiency of the fuel system. The filters and injectors within the system are prone to clogging due to the accumulation of impurities present in the degraded fuel.

 

Regular drainage helps maintain the efficiency of the system, prevent potential malfunctions and expensive repairs.

 

Improve reliability

 

The immediate starting ability of industrial diesel generators is crucial when encountering emergency situations or power outages. Discharging diesel and replacing it with fresh fuel can improve the performance of the generator and provide reliable power when needed most.

 

The behavior of discharging diesel from industrial diesel generators is important to ensure their service life and performance. This is an investment in power reliability that can reduce the risk of unexpected failures, minimize maintenance costs, and ensure that your generator is always ready to provide the energy needed for operation.

 

How to remove diesel from industrial diesel generators?

 

Discharging diesel from industrial diesel generators is an important procedure to maintain their optimal performance and service life. Please follow the following step-by-step instructions to ensure thorough and effective diesel emissions:

 

Safety first

 

Before starting any maintenance, please ensure that the generator is turned off and cooled down. Wear safety gloves and goggles to protect yourself from fuel contact.

 

Disconnect the power supply

 

Turn off the ignition system to prevent accidental start-up during maintenance.

 

Find the fuel shut-off valve

 

Understand the fuel shut-off valve. It is close to the fuel tank. Use a wrench to turn the valve to the "closed" position.

 

Run the generator

 

Start the generator and let it run until it stops. This ensures that the fuel line is empty. This reduces the remaining fuel in the system.

 

Add fuel stabilizer

 

If storing the generator for a long time, please add fuel stabilizers to the remaining fuel. This helps prevent fuel degradation during storage.

 

Remove the fuel pipe

 

Disconnect the fuel line from the generator fuel injection system using a manual pump, and connect the other end of the line to a suitable container.

 

Discharge fuel

 

Start pumping fuel into the container, ensuring that all fuel in the tank and fuel lines is collected.

 

Properly dispose of old fuel

 

Please comply with local regulations regarding the proper disposal of old fuel. Send it to an appropriate disposal facility or follow local safety disposal guidelines.

 

Reconnect the fuel pipe

 

After running out of fuel, reconnect the fuel line to the generator and turn the fuel shut-off valve to the "open" position.

 

Supplement fresh fuel

 

Supplement fresh and clean fuel to the generator to ensure optimal performance.

 

Reconnect the power supply

 

Reconnect to restore power to the ignition system.

 

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us