Home Products News Contact Us
Home > Supports > Diesel Generators > Nondestructive Testing of Jichai Diesel Generator Set

Nondestructive Testing of Jichai Diesel Generator Set

Jun. 08, 2023

The physical inspection of Jichai diesel generator set is to determine the technical state by using physical quantities such as electricity, magnetism, light, sound and heat, and to find internal defects through changes in components. It will not cause damage, separation or damage to the parts of Jichai diesel generator set. At present, this method is generally called nondestructive testing of Jichai diesel generator sets. For maintenance, this monitoring mainly includes regular inspection, maintenance inspection and operation inspection of spare parts.


open type diesel generator


It is also called magnetic flaw detection to judge whether there are cracks, cavities, uneven structures and other defects in the parts of Jichai diesel generator set by using the situation that the magnetic force line of Jichai diesel generator set passes through ferromagnetic materials. The principle of this method is to magnetize parts by inducing the magnetic field of strong DC inductance of Jichai diesel generator set. When the magnetic field of Jichai diesel generator set passes through permeable materials, the magnetic line of force will pass through in the shortest straight line.


If the internal structure of the parts of Jichai diesel generator set is uniform, the direction of the magnetic line of force passing through the parts of JICHAI diesel generator set is uniform. If there are defects in the parts of JICHAI diesel generator set, the defective parts will form large magnetoresistance. The magnetic field line will change direction, bypass the defect, gather around the defect, and expose a leakage magnetic field similar to the surface defect of the part.


When the iron powder of Jichai diesel generator set is evenly sprayed on the surface of the parts, the iron powder is adsorbed on the edge of the defect, thus showing the location and size of the defect. This method has the characteristics of high sensitivity, simple operation, fast and so on, but it is only applicable to the magnetizable parts of Jichai diesel generator set. On the surface of the parts of Jichai diesel generator set, if the defect depth of Jichai diesel generator set is deep, it is not easy to detect, Magnetic testing is widely used in production units.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us