Home Products News Contact Us
Home > Supports > Diesel Generators > Solution To Oil Leakage Of Different Parts Of Volvo Diesel Generator Set

Solution To Oil Leakage Of Different Parts Of Volvo Diesel Generator Set

Oct. 27, 2022

Volvo diesel generator sets sometimes leak oil during use. Jiangsu Starlight Electricity Equipments Co.,Ltd. will introduce solutions to different parts of Volvo diesel generator sets.

 

Oil leakage of Volvo diesel generator unit may be caused by oil leakage of oil pan gasket. Diesel oil leakage may be caused by the leakage of diesel oil at each interface of the fuel transfer pump and diesel filter. The solution to the oil pan gasket leakage of the diesel generator set is to replace the gasket. The method to replace the oil pan gasket is as follows:

 

(1) Use a socket wrench or box wrench to remove all the oil pan fixing screws diagonally.

 

(2) After removal, wipe the oil pan and the part of crankcase that contacts the gasket, apply sealant, and assemble the gasket after it is installed in order.

 

(3) During assembly, screw in the screws diagonally. Do not tighten one screw horizontally before tightening the second one. After all the screws are screwed on, gradually tighten all the screws according to the technical requirements.

 

Volvo diesel generator


The leakage of diesel oil at the interfaces of the fuel delivery pump and diesel filter of the diesel generator set is generally caused by damaged gaskets or loose oil return screws. The solutions are as follows:

 

(1) If the oil return screw is loose, the maintenance personnel should use a box wrench to tighten it to the specified torque.

 

(2) In case of oil leakage due to gasket damage, replace it with a new gasket.

 

The above is the solution provided by Jiangsu Starlight Electricity Equipments Co.,Ltd. to solve the problem of oil leakage of Volvo diesel generator set. I hope it will be helpful to you. If you still have other problems that cannot be solved in the use of diesel generator set, please contact us.

 

Founded in 1974, Jiangsu Starlight Electricity Equipments Co.,Ltd., a wholly-owned subsidiary of Jiangsu Starlight Power Group, is one of the earliest manufacturers of generating sets in China. Over the past 40 years, the company has won the recognition of users by relying on advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, strong R&D technology strength. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us