Home Products News Contact Us
Home > Supports > Diesel Generators > What is The Operating Mode of Diesel Generator?

What is The Operating Mode of Diesel Generator?

May. 23, 2024

What is the operating mode of a diesel generator? How are they different?


diesel generators


The application programs required for diesel, diesel generators have a series of operating modes. These operation modes can be widely defined, but they can also have scenarios where these modes are mixed.

 

The diesel generator operating mode or independent refers to the generator being the only power system. No power supply available. In this case, the generator is usually the only source of power. It can be used to charge alternative power sources (such as battery banks) to reduce overall operating time and fuel consumption.

 

Diesel generator in standby mode

 

Backup of power supply. When the power supply fails, the generator will start running and the Automatic Transfer Panel (ATS) will change the load from the power supply to the generator to increase to the load. Unless there is a short-term backup, such as a UPS system.

 

The diesel generator is connected in parallel with the main power supply.

 

Diesel generators are paired with the main power tank, which typically involves short-term power outages unless there is a short-term backup.

 

When the power supply is insufficient to meet the load demand, diesel generators can be used to provide additional power. It can also be used to export power to the power source to support the power grid. Generators in this mode are also commonly used for uniform power supply failures.

 

How do different operating modes affect design?

 

The operating mode of diesel generators may have different system designs. For example, generators running in parallel with the power supply will require synchronous equipment such as advanced control modules and fully automatic circuit breakers.

 

Generators operating in standby typically require a load switch system, such as a MANual or automatic transfer switch, to ensure safe isolation of generator power from the generator's power source. Generators operating in standby are usually additional, but other generator ISO ratings can also be used.

 

Generators operating in mode are usually the most basic and have almost no other equipment to operate. Common additional features include bulk fuel tanks to allow for extended periods of unattended running. These generators are usually rated as COP or PRP, depending on the load requirements.

 

Founded in 1974, Dingbo Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Dingbo quality is worth depending on. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us