Home Products News Contact Us
Home > Supports > Diesel Generators > Yuchai Diesel Generator Set Voltage is Lower Than Rated Voltage

Yuchai Diesel Generator Set Voltage is Lower Than Rated Voltage

May. 23, 2023

Yuchai diesel generator set protection function test Overspeed protection function test, over-current protection test, test, etc. Overvoltage protection test When a certain over-voltage occurs on Yuchai diesel generator set, the voltage protection device will alarm when it exceeds 10% of the rated value and 15% of the rated value. When it is close, the test of Yuchai diesel generator set is simulated or adjusted.


yuchai genset


When the voltage of Yuchai diesel generator set is less than 0.85 times of the rated voltage, the voltage protection device shall be able to alarm. When the voltage of Yuchai diesel generator set is lower than 0.7 times of the rated voltage, the voltage protection device shall be able to alarm and stop the protection, and test with simulation method or voltage regulator.


Overheating protection function: the short-circuit protection test of Yuchai diesel generator set can be completed through the short-circuit protective relay or circuit breaker. When a three-phase, two-phase or single-phase short circuit suddenly occurs outside the power station, the short circuit point shall be removed from the Yuchai diesel generator set to protect the Yuchai diesel generator set. The test can be carried out on a circuit breaker whose capacity is two or more stages larger than the unit circuit breaker.


When Yuchai diesel generator operates continuously under rated conditions, it shall continuously monitor and check whether the lubricating oil pressure/oil temperature/cooling water temperature of Yuchai diesel generator are at normal values.


Yuchai diesel generator is allowed to operate continuously under rated conditions. It shall be monitored continuously and checked every 30 minutes. The lubricating oil pressure of Yuchai diesel generator is generally 350-600 kPa, which should not be lower than 300 kPa.


The lubricating oil temperature of Yuchai diesel generator is generally between 60 ℃ and 150 ℃. The temperature should be stable after 1 hour of full load stable operation. The cooling water temperature of Yuchai diesel generator is generally between 70 ℃ and 95 ℃. Check the noise and leakage of Yuchai diesel generator body and accessories. If there is any abnormal noise, stop the inspection immediately and eliminate it.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us