Home Products News Contact Us
Home > Supports > Generator Sets > Analysis Of Water Leakage Of Diesel Generator During Operation

Analysis Of Water Leakage Of Diesel Generator During Operation

Jan. 29, 2023

When the diesel generator set operates: (1) There is abnormal noise at the water pump, fan, etc. (2) ① The radiator or the lower part of the diesel engine has water drop leakage. ② When the machine is working, the fan throws water around. ③ The water level in the radiator drops rapidly and the engine temperature rises rapidly. What is the reason for that?

 

(1) Water leakage.

① The radiator or the lower part of the diesel engine has water drop leakage.

 

② The fan throws water around when the machine is working.

 

③ The water level in the radiator drops rapidly and the engine temperature rises rapidly.

 

(2) Cause of failure.

① The radiator is broken.

 

② The rubber pipe of the radiator inlet and outlet pipe is broken or the clip screw is loose.

 

③ The drain switch is not closed tightly.

 

④ The water seal is damaged, the pump casing is broken or the gasket between the pump and the cylinder block is damaged.

 

diesel engine


(3) Generally speaking, the water leakage fault of diesel engine can be found by eye observation. If water flows out from the rubber pipe joint, the rubber pipe must be broken or the joint clamp is not tightened. At this time, the screw of the rubber pipe joint clamp can be tightened with a screwdriver. If the joint clamp is damaged, it needs to be replaced.

 

If there is no clip, it can be temporarily tied with iron wire or thick copper wire. If the rubber pipe is damaged, it should be replaced, or the broken part can be temporarily wrapped with adhesive tape. When replacing the rubber pipe, in order to facilitate insertion, a small amount of grease can be applied in the rubber pipe orifice.

 

If the water flows out from the lower part of the water pump, it is usually due to the damage of the water seal of the water pump or the lax closing of the drain switch. It should be flexibly handled according to the structural characteristics of various machines.

 

Founded in 1974, Jiangsu Starlight Electricity Equipments Co.,Ltd., a wholly-owned subsidiary of Jiangsu Starlight Power Group, is one of the earliest manufacturers of generating sets in China. Over the past 40 years, the company has won the recognition of users by relying on advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, strong R&D technology strength. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us