Water injection and outflow into the oil pan of Ricardo diesel generator is a serious problem. The Ricardo diesel generator should be shut down immediately, otherwise it will lead to major failure of Ricardo diesel generator, and the oil-water mixture in the oil pan will be ejected outward. If a small amount of oil pan exceeds the specified capacity, the movement of the Ricardo diesel generator crankshaft will cause the Ricardo diesel generator crankshaft oil seal to leak or eject from the filler. If a large amount of spray is applied, it should cause an excessive volume of high-pressure gas in the oil pan.
If the gasket of Ricardo diesel generator oil cooler is aged or damaged, replace the seal. The sealing gasket and the oil cold core are damaged by hydraulic test. If damaged, repair or replace the new oil cold core of Ricardo diesel generator. If the air cooler is installed and the air cooler core is damaged in the hydraulic test, repair or replace the new air cooler core of Ricardo diesel generator.
Whether the water blocking rubber ring of Ricardo diesel generator is aged or damaged. If it is aged or damaged, it will be replaced completely. Check whether the cylinder head is damaged by hydraulic test, and replace it if any. Check whether the cylinder bed of Ricardo diesel generator is washed. If it is washed, it needs to be replaced. Check whether the copper sleeve sealing rubber ring of Ricardo diesel generator fuel injector is aging or damaged. If it is, replace it with a new one.
Check whether the copper bushing of the fuel injector of Ricardo diesel generator is loose or damaged. If so, repair or replace it. Check whether the body of Ricardo diesel generator is frozen under high or low temperature environment, which causes the water circuit of Ricardo diesel generator body to crack and the oil enters the lubricating oil channel. Too much oil is injected into the oil pan of Ricardo diesel generator, which will also make the oil flow out of the oil gauge port. Pull out the oil gauge to see if it exceeds the maximum scale. If so, it is necessary to remove the excess parts.
Guangxi Dingbo Generator Set Manufacturing Co.,Ltd was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo Power has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences