With the development of technology, more and more mechanical equipment will have protective measures. The use of any mechanical equipment is based on safety, and dangerous things will have protective and preventive measures, including diesel generator sets. It is necessary to install protective devices for generator sets that have been operating for a long time and generate mechanical and electrical energy during the operation process.
The four protections of diesel generator sets include: low oil pressure protection, high water temperature protection, overcurrent protection, and overload protection.
1. When the oil pressure in the generator is low or reaches the warning level, the oil pressure protection system will start working, and the generator set will also issue a low oil pressure alarm and shut down; When the engine fuel supply system malfunctions, the overspeed protection system of the diesel engine starts working, immediately pulling the fuel cut-off valve to shut down the engine.
2. When the water temperature is high, when the water tank temperature of the generator set reaches 98 degrees or above, the control module of the generator will detect the high water temperature warning and stop for protection;
3. When the user's load exceeds the rated current of the generator set during overcurrent, the temperature system will start working and the generator set will also issue a shutdown alarm;
4. When the user's load exceeds the rated power of the generator during overload, the generator will also trigger an alarm and shut down.
In addition, there are many other protective parameters for the generator set, such as low voltage, short circuit, etc., which can be customized according to different customer needs. Advanced diesel generators will also have Chinese fault records to remind mechanics to check the cause of the fault, troubleshoot the generator, and ensure the normal operation of the unit. Main technical parameters of diesel generator set: 3-1000kw, altitude of diesel generator: 0-2000m, relative temperature: ≤ 95%, ambient temperature: -10 ℃ -40 ℃, power supply voltage: 12V/24V, contact output current: 25A, overspeed protection: ≤ 45Hz-65Hz (adjustable) low oil pressure: 0.02MP oil temperature: ≤ 95 ℃ -100 ℃ water temperature: ≤ 95 ℃ -98 ℃.
Attention: Setting protection parameters for diesel generator sets must be done by professional generator set technicians. Non professional operators are prone to setting incorrect parameters, which can lead to diesel generator set failures and reduced service life. Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences