Home Products News Contact Us
Home > Supports > Generator Sets > Diesel Validity Period of Diesel Generators

Diesel Validity Period of Diesel Generators

Apr. 07, 2024

Commercial diesel generators have been widely used. Its function is to convert the chemical energy extracted from diesel into kinetic energy. In the long run, people who use it as commercial power generation equipment will gain various benefits. Therefore, how should generators store fuel diesel for a long time?


diesel generator container


How long can diesel be stored.

 

If you ask this question to different people, the answer you get may be different. Because the storage life of any fuel is related to environmental conditions. It is important to let the fuel cool and dry. Diesel fuel can be stored for 6-12 months under ideal conditions. To extend the service life to more than 12 months, even under the best conditions, fuel stabilizers and fungicides need to be used. If the fuel continues to remain below 21 ℃, then 12 months is the longest reasonable storage prediction. Remember, it uses diesel instead of ethanol or biodiesel.

 

Storage tanks and regulations.

 

Over time, the greatest benefit of good maintenance of oil tanks is to prevent fuel from being contaminated by water. It is obvious that maintaining the structural integrity of the fuel tank is important, especially with the opening on the ground oil tank. When fuel deteriorates over time, rainwater can contaminate the fuel.

 

After a period of time, experts from Dingbo Power suggested minimizing the remaining water in the water tank as much as possible, which would affect the accumulation of condensed water in the fuel. The minimum space depends on the structure of the storage tank and the amount of oil (due to expansion).

 

It depends on whether the fuel is stored on the ground or on the ground. Strictly speaking, if more than 10% of the storage tanks are underground, it is defined as underground. The measures that equipment should take to prevent leakage and address potential corrosion issues that may develop over time.

 

Maintain diesel storage stability.

 

If other methods are used, stabilizing fungicides and diesel fuel can avoid most fuel storage issues. Fungicides can kill the growth of active diesel fuel bacteria in the fuel tank, and stability treatment can prevent fuel from decomposing due to external chemical reactions.

 

Due to the fact that ULSD's sulfur removal is more prone to microbial activity than before, fungicides have become an important tool in diesel fuel storage. So, although controlling the water content in fuel storage is very important, even if you want to do so, microbial issues can still create many problems.

 

It should be kept in mind that the presence of biofilm or biomass produced by organisms can affect the rate at which fungicides kill microorganisms in the fuel. If that's not the case, bacteria will be infiltrated by fungicides, and unless the biofilm is damaged, the storage system will become infected again after treatment. When a large amount of biofilm accumulates, the sink must be mechanically cleaned.

 

The purpose of stabilization treatment is to store the oxidation and acid-base reactions in the fuel. Oxidation is a conjecture that exposes fuel to oxygen. Oxygen interacts with reactants already present in the fuel. This will cause a chain reaction, transforming healthy stable molecules in the fuel into unstable reactive molecules, ultimately causing the fuel to darken and stratify. Firstly, antioxidants can effectively interrupt chain reactions, so they will not occur further. Under the same method, fuel stabilizers can also prevent harmful acid-base reactions and react with other fuel reagents by reacting with acidic precursors in the fuel. This is particularly important for fuels that come into contact with copper, iron, and other metals, as they can catalyze or accelerate harmful reactions. Only a small amount of dissolved metal can accelerate the reaction. You can solve this problem with an antioxidant stabilizer containing a metal passivator.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us