Home Products News Contact Us
Home > Supports > Generator Sets > 1600KW Yuchai Diesel Generator for Sale

1600KW Yuchai Diesel Generator for Sale

Aug. 17, 2023

Recently, Guangxi Dingbo sold a 1600kw Yuchai diesel genset. The generator set is used for emergency standby power supply of hotel. Our company provides transportation, installation, commissioning, training and other services.

 

The supporting power of the Yuchai generator set purchased by the user this time is all high-quality diesel engines produced by Yuchai itself, with low fuel consumption rate and lubricating oil consumption rate. In addition, the generating set has small vibration, low noise and low emission, which meet the national environmental protection standards.


 Yuchai Power generator set


1. Main technical specifications of 1600kw diesel generator

Model: DB-1600GF

Supplier: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Prime power: 1600kw, standby power:1760kw

Rated current: 2880A

Voltage: 230/400V, speed: 1500rpm, frequency: 50Hz, power factor: 0.8lag

Diesel engine: Yuchai YC12VC2700-D31

Alternator: Shanghai Stamford GR450H

Controller: SmartGen HGM6110CAN

Dimension( L x W x H): 5900 x 2650 x 2950mm

Gross weight: 18000KG

 

2. Technical specifications of Yuchai engine YC12VC2700-D31


YC12VC series engine developed independently by Yuchai is a classic product. It is characterized by energy-saving and environment-friendly, excellent performance, compact structure, and reliability and durability; the indexes, such as pollutant emission, dynamic performance, economy, and reliability, reach the international advanced level.


Engine power: prime power: 1805 kW @ 1500 r/min

Standby power: 1985 kW @ 1500 r/min

Type: Vertical, V-type, water-cooled, four-stroke

Aspiration: Turbocharged & Intercooled

Type of combustion chamber: Direct injection ω type

Number of cylinders - bore x stroke: 12 cylinders, 200 x 210mm

Number of per cylinder valves: 4

Displacement: 79.17L

Compression ratio: 13.5:1

Cylinder type: Wet cylinder liner

Firing order: B1-A6-B5-A2-B3-A4-B6-A1-B2-A5-B4-A3

Viewed from the back end: numbered starting from 1, with A for left side, and B for right side

Fuel supply system: Electronic unit pump

Lubrication method: Pressure & splash

Starting mode: Electronic

Oil capacity: 310L

Oil-fuel ratio: ≤0.3%

Rotation: Counterclockwise (viewed from the flywheel end)

Minimum no-load speed:(600~650)r/min

Speed control performance level: ISO 8528 G3

Noise Lp: 106dB(A)

 

3. Technical specifications of Shanghai Stamford GR450H


Standard based on GB/T 15548-2008B, IEC60034-1, IEC60034-22, ISO 8528.3, GB755, JB/T 3320.1, JB/T 10474 and EN 60034-1, EN 60034-22.

Prime power: 1600kw, standby power: 1760kw

Rated voltage: 230/400V, speed: 1500rpm, frequency: 1500rpm, power factor 0.8lag

Temperature rise grade: H

Insulation grade: H

Wire connecting method: Y type, 3 phase 4 wire

Alternator type: Self-excited, brushless

AVR type: Electronic

Protection level: IP23

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. is a leading factory for diesel generator in China, was set up in 2006. Its product covers Cummins, Perkins, Volvo, Shangchai, Yuchai, Weichai, Ricardo, MTU, Wuxi power etc. If you are interested in diesel generator, welcome to contact us.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us