The battery of diesel generator set is used to start the diesel generator set. When its service life expires or the user does not pay attention to regular maintenance and the battery is scrapped in advance, it needs to be replaced with a new battery. Diesel generator set battery replacement is also a technical activity. You need to be very familiar with the battery, otherwise the positive and negative poles will not be able to start the generator set, and the battery may be damaged. The following Jiangsu Starlight Electricity Equipments Co.,Ltd. will introduce you to the correct method of replacing the battery of the diesel generator set.
1. Turn the key start switch of the diesel generator set to the off position, then remove the key and remove all electrical loads.
2. Turn off the battery charger and disconnect the charger.
3. The negative cable connects the negative terminal of the battery to the ground. Disconnect the cable from the negative terminal of the battery.
4. The positive cable connects the positive terminal of the battery to the starting motor. Disconnect the cable from the positive terminal of the battery.
5. Remove the used battery.
6. Install a new battery. Note: Before connecting the cable, make sure that the key start switch is in the de-energized position.
7. Connect the cable from the starting motor to the positive terminal of the battery.
8. Connect the cable from the ground to the negative terminal of the battery.
The above is the complete battery replacement method. Jiangsu Starlight Electricity Equipments Co.,Ltd. reminds that smoking is strictly prohibited during maintenance and replacement of the battery. At the same time, ensure that the battery placed in a closed place has good ventilation, because the battery will release flammable gas that may explode and sparks. This flammable gas may be ignited to cause an explosion, causing a safety accident. The replaced used batteries should not be thrown away at will, and should be sent to an appropriate recycling place for recycling.
Jiangsu Starlight Electricity Equipments Co.,Ltd. was founded in 1974, as a wholly-owned subsidiary of Jiangsu Starlight Power Group, it is one of the earliest manufacturers of generator sets in China. Starlight Power has 64 sales services, long-term technical advice for users, free debugging, free maintenance, free training services. For more details, please contact us with [email protected]
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences