Home Products News Contact Us
Home > Supports > Generator Sets > Inspection Method for Oil Supply Increase of Shangchai Diesel Generator Set

Inspection Method for Oil Supply Increase of Shangchai Diesel Generator Set

Jul. 25, 2023

The starting speed of Shangchai diesel generator set is normal, the cylinder of Shangchai diesel generator set has no explosion sound, and the exhaust smoke is white. Through this phenomenon, it shows that diesel does not burn in the diesel generator set of Shanghai Diesel, and exhaust steam or too much water is formed in the diesel. First, check whether the ambient temperature of Shangchai diesel generator set is too low when starting, and then check whether there is air or moisture in the oil pipe of Shangchai diesel generator set.


shangchai generators


The pipe joint is not firmly fixed, the needle valve of the nozzle of Shangchai diesel generator set is blocked, and the diesel in the oil tank is exhausted before the shutdown of Shangchai diesel generator set, which may cause the air of Shangchai diesel generator set to enter the diesel supply system. In this way, when the plunger of the injection pump of the diesel generator set is pressurized, the air entering the oil passage is compressed, and the oil pressure cannot rise. When the injection pump column of Shangchai diesel generator set is plugged with oil, the air volume expands, affecting oil absorption.


Therefore, if the fuel supply of the diesel generator set increases or decreases, the inspection method for this fault is to loosen the exhaust screw on the filter of the diesel generator set, the exhaust screw on the fuel injection pump or the high-pressure fuel pipe on the fuel injection pump, and then turn the diesel generator set. If bubbles appear, it indicates that there is air in the diesel supply system. The treatment method is to tighten the joints at each part of the oil pipe first, then loosen the bleed screw on the injection pump of the diesel generator set, rotate the crankshaft of the diesel generator set until there is no bubble in the oil, and then tighten the bleed screw to start the machine.


If water is found in the diesel oil of Shangchai diesel generator set, the same method can be used to check and find out the reason for water in the diesel oil of Shangchai diesel generator set, and replace the diesel oil in the fuel tank of Shangchai diesel generator set as required. If there is no air or water mixed in the diesel, it is necessary to continue to check whether the performance of the fuel injector of the diesel generator set is good and whether the timing of fuel supply and distribution is appropriate.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us