Home Products News Contact Us
Home > Supports > Generator Sets > Knowledge About Diesel Generator Sets Used In Hospitals

Knowledge About Diesel Generator Sets Used In Hospitals

Aug. 19, 2023

In daily life, insufficient power supply brings many inconveniences to our production and life. It is a good solution to use the backup power supply for power supply, and the generator set as the backup power supply can choose the diesel generator. The power range of diesel generators is 8-2000kw, with less fuel consumption and lower cost. It is suitable for slightly larger projects and can save a lot of costs. The startup time of diesel generators usually only takes a few seconds, and in an emergency state, the full load is carried within 1 minute, which means that the startup is fast and can reach full power quickly. The shutdown period of diesel generators is also very short and can be stopped frequently. Therefore, the diesel generator set is very suitable as a backup emergency or backup power supply for the hospital, and the Dingbo Power diesel generator set can meet the special needs of the hospital's power supply.

 

Demands and Challenges of Diesel Generator Sets for Hospitals.

1. Standard at work.

 

The unit will work reliably under the following standards, the output power can continue to work for 24 hours at the rated power output method, the altitude does not exceed 1000 meters, the lower limit of ambient temperature is -15C°, and the upper limit is 40C°, other natural environment units can be used.

 

2. Low noise during work.

Ultra-low noise, with enough quiet and quiet natural environment to ensure that hospital doctors can work with peace of mind, especially in the operating room to carry out surgical treatment operations quietly, and generally ensure that patients can have a quiet rest and recuperation in the natural environment . The most common is to do noise reduction engineering in the computer room or purchase a silent box generator set.

 

600KW cummins power generator set


3. Critical and necessary protective equipment.

The unit startup method is selected as the automatic startup method. The unit must have the function of AMF (autonomous mains failure), and be equipped with ATS to realize automatic start-up. When the mains power fails, the start-up time delay is less than 20 seconds (adjustable), the unit can be started automatically (a total of 3 continuous self-starting functions), and the total negative conversion time of the unit is < 20 seconds, which completely meets the needs of the load. If the time is less than 30 seconds, after the mains returns to normal, the unit will keep running for 0-300 seconds and then shut down by itself after cooling down (adjustable).

 

4. Stable performance and strong stability.

The common failure cycle per capita of the unit is not less than 1000 hours. In terms of technical performance, the no-load working voltage setting range of the unit is 95-105% of the rated voltage.

 

The total weight and size of diesel generators are relatively large, and it is very likely that a generator room will have to be built, but others have high power, generate a lot of electricity, and bring a lot of power-consuming equipment. It is good to choose the appropriate generator set according to the specific power consumption. Diesel generators are used in large-scale public places or construction sites. The power effect is large, but relatively speaking, the noise is somewhat large, but it is very fuel-efficient. For public use, it is very economical.

 

Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. is one of the earliest manufacturers of generating sets in China. It has first-class testing equipment, advanced production technology, professional manufacturing technology, perfect quality management system, and strong R&D technical strength. It can provide 3KW-2500KW various specifications of universal, automatic, four protection, automatic switching, low noise and mobile, etc., high-quality, low-energy generating sets to meet all customers' power needs, and can also meet users' different voltages and different Frequency requirements, as well as the parallel-connected power supply system of multiple units, use excellent talents to build excellent enterprises, create excellent products, create excellent services, and strive to build excellent domestic enterprises. For more product details, please contact us with sales@dieselgeneratortech.com.


Contact Us +

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us

x