Home Products News Contact Us
Home > Supports > Generator Sets > Maintenance Method of Diesel Generator Set in Humid Environment

Maintenance Method of Diesel Generator Set in Humid Environment

Jul. 24, 2023

In a humid environment, the insulation performance of diesel generator set and electrical components will be reduced due to moisture, and metal parts will be corroded, which will cause accidents in serious cases. Therefore, careful maintenance must be carried out. In this article, Dingbo Power will share the maintenance methods of two diesel generator sets in humid environment.


diesel generator set


(1) Frequently pay attention to the insulation performance of the electrical components and circuits of the unit. When there is a fault, the insulation monitoring indicator light will light up, and the cause should be carefully checked and eliminated. If it drops due to moisture, the motor winding needs to be baked to restore its insulation performance. Usually, external heating method or current passing method inside the coil are used to evaporate the moisture in the motor winding; Or start the unit and adopt a gradual loading method to gradually increase the current inside the motor and drive out moisture, achieving the goal of self drying. For units operating in humid areas, it is best to use them frequently. If they are not used for a long time, they should be loaded and run for 1 hour every month to ensure good insulation performance.


(2) Metal parts in humid environments are prone to corrosion and rust on their surfaces, and it is necessary to pay attention to protecting the paint coating well. If there are any peeling or other phenomena, they should be promptly repainted or coated with grease for protection. The contact surfaces of each moving component should be kept attached to the lubricating oil layer. If the unit is not in use for a long time, the starting device should be manually pulled every week to make the crankshaft rotate and cover the surface of each friction part in the cylinder with lubricating oil to achieve anti-corrosion effect.


Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo Power units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo Power was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Power Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo Power generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us