Home Products News Contact Us
Home > Supports > Generator Sets > Reasons for The Burning of Tiles in Diesel Generator Sets

Reasons for The Burning of Tiles in Diesel Generator Sets

Aug. 19, 2023

The working load of diesel generator sets is heavy, the engine oil pressure will decrease, and there will be occasional "chirp" sounds. These are all "burning tiles" phenomenon of diesel generator sets. What are the reasons for this phenomenon? Dingbo power generation equipment tells you that there are different reasons for different diesel generator sets, as follows:


Yuchai Power Generator Set


1. Deterioration of engine oil. The deterioration of the oil is generally caused by the leakage of cooling water and fuel into the oil pan. In addition, the poor atomization of the injector, and the frequent banging of the accelerator when the engine is working will also cause the diesel engine to fail to burn completely, causing the oil to deteriorate.


2. Impurities such as sand particles and metal chips entering the oil channel cause tile burning. The oil pump is damaged and the oil supply is stopped, the quality of the bearing bush is unqualified, the fit between the journal and the bearing bush changes, the oil passage is blocked, the lubricating oil cannot be sent to the friction place, and the insufficient oil pressure will cause the bush to burn. Oil leakage is an important cause of insufficient oil pressure. These are very important diesel generator set accessories.


3. The oil level is too low, the tractor goes uphill, accelerates and brakes, etc., which may cause the oil filter to be exposed to the oil level, and the suction air surface cannot supply oil. Burn tiles.


4. Other reasons such as misuse of oil, frequent overloading, excessive load, or overtightening of the oil pressure limiting valve bolts, resulting in excessive oil pressure, and long-term low-load operation may also burn tiles. It should be avoided to reduce failures.


If you encounter the phenomenon of "burning tile" when using the diesel generator set, you must immediately turn off the switch, remove the cover connecting rod bearing, and determine the reason for repair and replacement. If you have more knowledge about diesel generator set technology, please come to Dingbo website for consultation, we will serve you wholeheartedly.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 9.5 million yuan. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us