Home Products News Contact Us
Home > Supports > Generator Sets > Volvo Generator Set Governor Automatic Operation System

Volvo Generator Set Governor Automatic Operation System

Aug. 14, 2023

The speed governing system and Volvo generator set equipment have been installed, the Volvo generator set has passed the commissioning, the pressure and oil level of the oil pressure device are normal, the turbine oil has passed the test, and the meters, valves, and automation components of all parts have been set to meet the requirements. The oil pump of oil pressure unit operates normally under the working pressure of Volvo generator set, without abnormal vibration and heating, and the oil level relay of oil sump operates normally. The action of the high-pressure air make-up device is correct during manual and automatic operation, and the manual and automatic commissioning of the oil leakage device are qualified.


The pressure oil of the oil pressure device of the Volvo generator set is led to the speed governing system by manual operation. The governor locking device of the Volvo generator set is qualified for commissioning and should be locked before water filling. Carry out the manual operation of the linkage commissioning of the speed regulation system, and check the flexibility and reliability of the linkage operation of the governor, servomotor and water guide mechanism of the Volvo generator set and the stability of the action within the full stroke. Check the consistency of the guide vane opening indicator of the governor cabinet, and record the relationship curve between the guide vane opening and the servomotor stroke, which should meet the design requirements.

cummins power generator set

For the Kaplan turbine of Volvo generator sets, the regulator of Volvo genset shall be used to check the consistency between the blade rotation indicator and the actual opening, and simulate the association relationship curve of guide vane and blade under various water heads. Simulate the operation test of the automatic operation system of the governor of Volvo generator set, and check the accuracy and reliability of the actions of all parts of the automatic startup, shutdown and emergency shutdown of Volvo generator set. Collect the liquid thrown out by the impeller to reduce the liquid flow rate of Volvo generator set. After some velocity energy heads are converted into pressure energy heads, they are uniformly introduced to the next stage or discharged through the diffusion tube.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 9.5 million yuan. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us