Home Products News Contact Us
Home > Supports > Generators > Causes of Silent Diesel Generator Sets Trip

Causes of Silent Diesel Generator Sets Trip

Mar. 09, 2022

There will be a tripping phenomenon during the use of the silent diesel generator set, so do you know what are the reasons for the tripping of the silent diesel generator set? In this article, the Starlight Power Generation Equipment will be introduced to you:


quiet diesel generator


1. Check whether the indicator device of the silent diesel generator set has obvious fault symbols. Sometimes the excitation should be cut off immediately. If there is no abnormal symbol, the duty personnel should adjust the generator voltage and frequency within the normal range when the machine and furnace are in good condition. , check whether the high-voltage power supply of the unit is tripped, and whether the starting transformers are connected to each other. Is the power supply normal.


2. According to the accident phenomenon and relay protection action, determine the nature and scope of the fault, and conduct a detailed external inspection of the transformer group and related equipment of the silent diesel generator set to determine whether there are external fault characteristics.


3. If the over-current protection of the silent diesel generator set is caused by the busbar differential, or the over-current protection of the silent diesel generator set is caused by the fault of the substation, check that the external of the generator is normal. After the fault is isolated, contact the network to adjust and connect to the power grid.


4. Before the trip, such as strong excitation, there is a current impact, which reflects the main protection (differential, heavy gas, etc.) of the internal fault of the generator-transformer group of the silent diesel generator set. The power grid is running normally, and it should be dealt with at this time.


5. If there is no strong excitation, there is no inrush current before the trip, the power grid is running normally, the engine and furnace are normal, the water and hydrogen oil systems of the generator and main transformer of the silent diesel generator set are normal, such as checking the silent diesel generator set and its circuit ; Check the action protection, such as all normal generators can start with zero voltage. If all goes well during the boost process, the generator can be connected to the grid and continue to find out why.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Contact Us +

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us

x