Reasons for Cylinders Water Overflow of Cummins Diesel Generator Sets

Dec. 17, 2021

Cummins diesel generator set cylinder overflow problem can be divided into two specific reasons: Cummins diesel generator set cylinder head gasket is washed out, or Cummins diesel generator set cylinder head nut tightening torque is insufficient. In this article, Starlight Power generation equipment will be introduced in detail.


commercial generators.jpg


1. The water pump of Cummins diesel generator set is faulty. We must first check whether the water pump works well. If it is found that the water pump drive gear shaft is worn out, it means that the water pump has no effect, and it needs to be replaced before the circulation is normal.


2. The coolant level of Cummins diesel generator set is too low or not in compliance with regulations. If the liquid level is too low, it can directly cause the coolant temperature to rise so that the coolant does not circulate. The coolant according to the rules is 50% antifreeze + 50% softened water + DCA4. If it does not comply with the rules, it will cause pipeline blockage and occur in the pipe wall. Rust, so that the coolant can not circulate normally.


3. Shortcomings of Cummins diesel generator thermostat. A thermostat is installed in the combustion chamber of the engine to control the temperature of the combustion chamber of the engine. The thermostat must be opened completely at the regulated temperature to facilitate small circulation. If there is no thermostat, the coolant cannot maintain the circulating temperature, and low temperature may occur. Call the police.


4. Air is mixed in the cooling system of the Cummins diesel generator set, and the pipeline is not dredged. Damage to the suction valve and exhaust valve on the expansion tank will also directly affect the circulation. At this time, you should always check whether their pressure values comply with the rules and inhale. The pressure is 10kpa and the exhaust pressure is 40kpa. In addition to this, whether the exhaust pipe is unblocked is also an important reason that affects the circulation.


5. The radiator fin of Cummins diesel generator set may be blocked or damaged. The radiating fan does not work or the radiating fins are blocked, so that the temperature of the cooling liquid cannot be lowered, and the radiating fins are rusty, which constitutes a liquid leakage phenomenon and can also constitute a poor circulation.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to sales@dieselgeneratortech.com.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us