Home Products News Contact Us
Home > Supports > Generators > Reliability Check of Perkins Diesel Generator Set Automatic Function

Reliability Check of Perkins Diesel Generator Set Automatic Function

Mar. 15, 2023

When checking the Perkins diesel generator set, one of the most important contents is the reliability check of the automatic function of the diesel generator set. If there is a problem with the automatic function of the unit, it may not be able to stop automatically when emergency shutdown is required, thus causing some more serious faults. Today Starlight will introduce to you the aspects of reliability inspection of automatic function of diesel generator set.


perkins silent diesel generator


1. The Perkins diesel generator set shall be able to start automatically after receiving the start command of automatic control or remote control.


2. When the Perkins diesel generating set fails for the third time after the automatic start, the start failure signal shall be sent; When a standby unit is set, the program startup system shall be able to automatically transmit the startup command to another standby unit.


3. The time from the automatic start command to power supply to the load shall not exceed 3min.


4. After the automatic start of the Perkins diesel genset is successful, the first load shall not be less than 50% of the rated load.


5. The unit shall be able to stop automatically after receiving the shutdown command of automatic control or remote control; For the standby units used in conjunction with the mains power grid, when the grid returns to normal, the Perkins diesel generator set shall be able to automatically switch or automatically stop, and its shutdown mode and shutdown delay time shall comply with the product technical conditions.


6. Automatic startup success rate. The success rate of automatic startup shall not be less than 99%.


7. Requirements for no-load voltage setting range. The no-load voltage setting range of the unit shall not be less than 95% - 105% of the rated voltage.


8. Automatic supply function requirements. The Perkins diesel generator set shall be able to automatically charge the starting battery.


9. Automatic protection function requirements. The Perkins diesel generator set shall be protected against phase loss, short circuit (no more than 250KW), overcurrent (no more than 250KW), overspeed, high water temperature and low oil pressure.


When checking the reliability of the automatic function of the Perkins diesel generator set, only those that meet all the above requirements can be considered as qualified and can be put into use. Since the automatic function is more important for the unit, when the above requirements are not met, you must not have the idea that it will not affect the use of the unit. You must repair it in time and put it into use after passing the inspection.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us