Home Products News Contact Us
Home > Supports > Generators > Requirements for Parallel Connection of Tongchai Diesel Generator Set

Requirements for Parallel Connection of Tongchai Diesel Generator Set

Jun. 02, 2023

The parallel connection of Tongchai diesel generator set must first meet the requirement of uniform distribution of power. The uniform distribution of power of Tongchai diesel generator set includes active power and reactive power. The so-called uniform distribution means that the active and reactive power of each diesel generator set shall be proportional to its rated power. China has clear requirements for the distribution of diesel generator sets connected in parallel. When the load of Tongchai diesel generator set changes within 20% - 100% of the total rated power, Tongchai diesel generator set shall be able to operate stably.


chinese generator


If the active power distribution of the parallel connected diesel generator set is seriously unbalanced, when the total load power of the diesel generator set is large, one diesel generator set is usually full load or overload, while the other diesel generator set is still under light load, so the diesel generator set cannot fully use and play the efficiency of the whole power station. Overload of Tongchai diesel generator set will not only harm the diesel engine or generator, but also cause the action of Tongchai diesel generator set protection device, affecting the operation of the whole power station of Tongchai diesel generator set.


When the total load power of Tongchai diesel generator set is very small, the imbalance of active power will often cause the active circulation between Tongchai diesel generator sets, making some Tongchai diesel generator sets enter the motor state, which is also not allowed by Tongchai diesel generator sets. When Tongchai diesel generator set has reverse power protection, reverse power phenomenon will cause reverse power tripping and cause fault. For diesel power plants with frequent and significant load changes, the above situations should be given more attention. The uniform distribution of power between Tongchai diesel generator sets in parallel operation is not only a problem of economic operation of Tongchai diesel generator sets, but also an important factor to ensure the power supply reliability of the whole Tongchai diesel generator set plant.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us