Once you decide to install a new industrial generator in your factory, you need to adopt the correct generator installation plan. There are many factors that can affect the successful installation of diesel generators to ensure their normal operation and reliability in the coming years. Dingbo Power recommends that you follow the following important steps to ensure that your generator is installed in a safe and effective manner:
Pre installation
This is the initial stage of installing a new industrial generator. You need to consider:
Computational power
In the pre installation phase of the project, you need to start by calculating the electricity required for the building or facility. The electricity demand varies by industry, from small 35kW commercial generators as backup power sources for specific equipment to large 2500kW power plant installations in water treatment plants, data centers, factories, hospitals, university campuses, etc. At Dingbo Power Company, we have spent over a decade building strong relationships with power generation experts from all over the country. We will work with them to determine your electricity needs (primary, backup, or both) and select suitable industrial generators based on your needs.
Plan your concrete foundation
Once you know the type and size of the generator, it's time to plan a suitable concrete foundation. The shape, size, footprint, and weight of the concrete foundation are all suitable for your generator. A foundation that is too small in size can cause many problems, including:
Insufficient space to safely install the generator
Insufficient space for entry and maintenance
Your cushion is overloaded, causing it to break
Not in compliance with laws and regulations, may result in fines or generator shutdown
Take some time to study the concrete foundation design of your generator and plan a high-quality foundation that is suitable for the size and location of your new industrial generator. Our team at Dingbo Power Company can help you find a reliable contractor who excels in concrete foundation layers and design, no matter where you are. These experts have advanced methods for calculating foundation thickness, which will enable them to determine the perfect thickness of the generator concrete pad to avoid cracking.
In many cases, your generator's concrete foundation pad specifications also require vibration insulators. This ensures that the vibration generated by the generator does not enter your factory, avoiding interference with sensitive equipment and employees. The concrete foundation design calculation for the generator will allow your lining contractor to evaluate the vibration specifications of your generator and explain this through correct concrete lining and insulation design.
Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences