Home Products News Contact Us
Home > Supports > Generators > Structure and Performance of Automatic Diesel Generator Set

Structure and Performance of Automatic Diesel Generator Set

Oct. 08, 2022

Generally speaking, customers often do not have a deep understanding of the automation functions of diesel generator sets. Its structure and application The unit adopts advanced control system, which can automatically start the unit to supply power in case of mains power loss and undervoltage. So, what advanced performance does such an excellent automatic diesel generator set have?


genset generator


1. Automatic start and input function

When the mains power grid stops supplying power or the mains voltage is lower than 80% of the rated value, the unit will start automatically. After the start is successful, power will be supplied to the load. The whole process of a successful start is controlled within 15 seconds. With a remote interface, the start delay can be set to realize the automatic start and stop of the diesel generator set.


2. Auto exit function

During the self generating output of the unit in the automatic state, if the unit starts to execute the automatic exit procedure after the mains power is restored and confirmed for 30 seconds, the unit will first cut off the load, restore the mains power supply, and then automatically shut down after the cold machine runs for 2 minutes. If the mains supply stops during the operation of the chiller, the unit will automatically speed up and resume power supply to the load.


3. Pre alarm/fault protection function

Low battery voltage, charging failure, over-current, low oil pressure, high water temperature have the pre alarm function, that is, the value does not stop when the alarm is given, and the alarm light flashes; When the value exceeds the shutdown value, the oil engine fails and shuts down. There are fault protection functions for low speed, overspeed, frequency overrun, voltage overrun, emergency stop, and startup failure. If the input value of a certain analog quantity is greater than the upper limit or less than the lower limit, the corresponding high/low delay will start. After the delay is over, the value throw does not return to normal, the oil engine will immediately shut down due to fault, and the alarm light will stay on.


4. Automatic charging function

The unit can automatically charge the starting control battery during mains or self generation. The charging system adopts switching power supply, which can realize two-stage charging of the battery. In the first stage of charging, when the battery capacity is low, constant current 6ADC charging is adopted. When the battery voltage reaches 26.5VDC, constant voltage charging is switched to and floating charge is maintained. When the battery is fully charged, the charging current is automatically zero.


5. Manual function

The panel of the unit control system has automatic and manual functions. When the system works in manual mode, the unit can be started, installed and replaced at high and low speeds, power supply, shutdown, alarm signal light test and alarm release, self generation opening and closing, and mains power closing. The emergency stop knob is effective in both automatic and manual states. Do not use this button in case of emergency.


6. Overview of other functions

Use animated icon type alarm, fault display, high brightness, multi-color LCD to display parameters; Automatically record the running time of the unit; Compact and reasonable structure, stable and reliable performance.

It is clear from the above that the automatic diesel generator set can automatically receive information to start and alarm without manual operation. However, the configuration of automatic diesel generator sets is diversified, so the functions are different. Therefore, when purchasing units, appropriate unit configuration should be selected according to needs.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us