Home Products News Contact Us
Home > Supports > Generators > Warning Signal for Parallel Controller of Zhongzhi HGM9510 Generator Set 1

Warning Signal for Parallel Controller of Zhongzhi HGM9510 Generator Set 1

Jan. 03, 2025

When the parallel controller of Zhongzhi HGM9510 generator set detects a warning signal, the controller only warns and does not stop the machine. What do the warning signals of the controller represent? Top Power shares with users.


diesel generator set


1. Overspeed warning

 

When the overspeed warning is enabled, the controller sends a warning signal when it detects that the speed of the generator set exceeds the set overspeed warning threshold.

 

2. Underspeed warning

 

When the underspeed warning is enabled, the controller sends a warning signal when it detects that the speed of the generator set is less than the set underspeed warning threshold.

 

3. Speed signal loss warning

 

When the controller detects that the speed of the generator set is zero and the speed signal is lost, the action type selection warning is triggered, and the controller issues a warning signal.

 

4. Power generation over frequency warning

 

When the power generation over frequency warning is enabled, the controller sends a warning signal when it detects that the frequency of the generator set exceeds the set over frequency warning threshold.

 

5. Power generation under frequency warning

 

When the power generation under frequency warning is enabled, the controller sends a warning signal when it detects that the frequency of the generator set is less than the set under frequency warning threshold.

 

6. Overvoltage warning for power generation

 

When the overvoltage warning for power generation is enabled, the controller sends a warning signal when it detects that the voltage of the generator set is greater than the set overvoltage warning threshold.

 

7. Power generation undervoltage warning

 

When the power generation undervoltage warning is enabled, the controller sends a warning signal when it detects that the voltage of the generator set is less than the set undervoltage warning threshold.

 

8. Power generation overcurrent warning

 

When the overcurrent detection is enabled for power generation, the controller sends a warning signal when it detects that the current of the generator set is greater than the set overcurrent value and the overcurrent action type is selected as a warning.

 

9. Shutdown failure warning

 

After the delay of the generator set coming to a complete stop, if the engine does not come to a complete stop, the brake system will issue a warning signal.

 

10. Charging failure warning

 

When the charging failure warning is enabled, the controller sends a warning alarm signal when it detects that the charging voltage value of the generator set is less than the set threshold.

 

11. Battery overvoltage warning

 

When the battery overvoltage warning is enabled, the controller sends a warning alarm signal when it detects that the battery voltage value of the generator set is greater than the set threshold.

 

12. Battery undervoltage warning

 

When the battery undervoltage warning is enabled, the controller sends a warning alarm signal when it detects that the battery voltage value of the generator set is less than the set threshold.

 

13. Maintenance time up to warning

 

When maintenance is enabled, the controller sends a warning signal when the maintenance countdown is 0 and the maintenance time reaches the action type selection warning.

 

14. Reverse power warning

 

When reverse power detection is enabled, the controller sends a warning signal when it detects that the reverse power value (negative power) of the generator set exceeds the set threshold and the reverse power action type is selected as a warning.

 

15. Warning signal

 

When the over power detection is enabled, when the controller detects that the power value of the generator set (power is positive) is greater than the set threshold and the over power action type is selected as a warning, the controller issues an over power warning

 

16. ECU warning

 

When the controller receives a warning signal from the engine through J1939, it emits a warning signal.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to sales@dieselgeneratortech.com we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us