Home Products News Contact Us
Home > Genset > Starlight Diesel Generator Set Models | Cummins Perkins Volvo

Starlight Cummins, Volvo, Perkins, Shangchai, Yuchai, Deutz, Yuchai-MTU diesel generator models are given below:

Alternators can choose Stamford, Leroy-Somer, Marathon, CSIC Siemens, Engga, Starlight and Shanghai KEPU, etc.


DCEC Cummins Engine with Stamford Alternator

Generator

Model

PRP   KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-22GF

22/27.5

24/30

4B3.9-G2

PI144F1

1750x760x1300

800

XG-30GF

30/37.5

33/41.25

4BT3.9-G2

PI144J1

1750x760x1300

800

XG-50GF

50/62.5

55/68.75

4BTA3.9-G2

UCI224E14

1860x760x1300

900

XG-64GF

64/80

70/87.5

4BTA3.9-G11

UCI224G14

2150x830x1400

1100

XG-75GF

75/93.75

83/103.75

6BT5.9-G2

UCI274C14

2150x830x1400

1100

XG-90GF

90/112.5

99/123.75

6BTA5.9-G2

UCI274D14

2150x830x1400

1200

XG-100GF

100/125

110/137.5

6BTAA5.9-G2

UCI274ES14

2300x830x1400

1300

XG-120GF

120/150

132/165

6BTAA5.9-G12

UCI274F14

2300x830x1400

1300

XG-150GF

150/187.5

165/206.25

6CTA8.3-G2

UCI274G14

2400x850x1500

1700

XG-

160GF

160/200

176/220

6CTAA8.3-G2

UCI274H14

2510x850x1600

1800

XG-200GF

200/250

220/275

6LTAA8.9-G2

HCI444C1

2550x960x1650

2000

XG-300GF

300/375

330/412.5

6ZTAA13-G3

HCI444FS1

3270x1140x1800

3200

XG-350GF

350/437.5

385/481.25

QSZ13-G2

HCI544C1

3270x1140x1800

3200

XG-400GF

400/500

440/550

QSZ13-G3

HCI544C1

3270x1140x1800

3200

CCEC Cummins Engine with Stamford Alternator

Generator

Model

PRP   KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-200GF

200/250

220/275

NT855-GA

HCI444C1

3000x1040x1655

2800

XG-200GF

200/250

220/275

MTA11-G2A

HCI444C1

2740x1010x1700

2800

XG-220GF

220/275

242/302.5

NTA855-G1A

HCI444D1

3000x1040x1655

2600

XG-250GF

250/312.5

275/343.75

NTA855-G1B

HCI444ES1

3000x1040x1655

3000

XG-280GF

280/350

308/385

NTA855-G2A

HCI444E1

3000x1040x1655

3100

XG-300GF

300/375

330/412.5

NTAA855-G7

HCI444FS1

3270x1140x1800

3200

XG-360GF

360/450

396/495

QSNT-G4

HCI544C1

3400x1360x2070

4200

XG-400GF

400/500

440/550

KTA19-G4/G3A

HCI544C1

3400x1360x2070

4200

XG-

420GF

420/525

462/577.5

KTAA19-G5

HCI544D1

3600x1550x2200

4500

XG-500GF

500/625

550/687.5

KTA19-G8

HCI544FS1

3600x1550x2200

4500

XG-500GF

500/625

550/687.5

KTAA19-G6A

HCI544FS1

3600x1550x2200

4590

XG-520GF

520/650

572/715

QSK19-G4

HCI544F1

3600x1550x2200

4580

XG-580GF

580/725

638/797.5

KTA38-GA

LVI634B1

4200x1820x2250

7600

XG-600GF

600/750

660/825

KTA38-G2

LVI634B1

4200x1820x2250

7600

XG-

640GF

640/800

704/774.4

KTA38-G2B

LVI634C1

4200x1820x2250

7700

XG-720GF

720/900

792/990

KTA38-G2A

LVI634D1

4200x1820x2250

7800

XG-800GF

800/1000

880/1100

KTA38-G5

LVI634E1

4400x1820x2250

8000

XG-900GF

900/1125

990/1237.5

KTA38-G9

LVI634F1

4400x2080x2350

9400

XG-1000GF

1000/1250

1100/1375

KTA50-G3

LVI634G1

4870x2100x2350

10000

XG-1100GF

1100/1375

1210/1512.5

KTA50-G8

PI734B1

5620x2280x2350

11000

XG-1200GF

1200/1500

1320/1650

KTA50-GS8

PI734C1

5620x2280x2350

11000

XG-1500GF

1500/1875

1650/2062.5

KTA50-G15

PI734E1

5620x2280x2350

11000

Volvo Penta Engine with Leroy-Somer Alternator

Generator

 Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-68GF

68/85

75/93.75

TAD530GE

LSA44.3 S4

2200x720x1380

1050

XG-80GF

80/100

88/110

TAD531GE

LSA44.3 S5

2200x720x1380

1200

XG-100GF

100/125

110/137.5

TAD532GE

LSA44.3 M6

2300x720x1380

1250

XG-120GF

120/150

132/165

TAD731GE

LSA44.3 L10

2600x1000x1650

1480

XG-150GF

150/187.5

165/206.25

TAD732GE

LSA44.3 L13

2600x1000x1650

1500

XG-160GF

160/200

176/220

TAD733GE

LSA44.3 L14

2650x1070x1650

1550

XG-200GF

200/250

220/275

TAD734GE

LSA46.3 S5

2650x1070x1650

1650

XG-250GF

250/312.5

275/343.75

TAD1341GE

LSA46.3 L10

3000x1100x1750

2300

XG-250GF

250/312.5

275/343.75

TAD1351GE

LSA46.3 L10

3000x1100x1750

2300

XG-300GF

300/375

330/412.5

TAD1343GE

LSA46.3 L11

3100x1200x1750

2900

XG-300GF

300/375

330/412.5

TAD1352GE

LSA46.3 L11

3100x1200x1750

2900

XG-350GF

350/437.5

385/481.25

TAD1344GE

LSA47.2 S5

3100x1200x1750

2950

XG-350GF

350/437.5

385/481.25

TAD1355GE

LSA47.2 S5

3100x1200x1750

2950

XG-360GF

360/450

396/495

TAD1345GE

LSA47.2 S5

3100x1200x1750

2950

XG-380GF

380/475

418/522.6

TAD1650GE

LSA47.2 M7

3200x1160x2022

3000

XG-400GF

400/500

440/550

TAD1641GE

LSA47.2 M7

3200x1160x2022

3100

XG-400GF

400/500

440/550

TAD1651GE

LSA47.2 M7

3200x1160x2022

3100

XG-500GF

500/625

550/687.5

TWD1652GE

LSA49.3 S4A

3200x1160x2022

3200

XG-500GF

500/625

550/687.5

TWD1643GE

LSA49.3 S4A

3460x1400x2100

3300

XG-520GF

520/650

572/715

TWD1653GE

LSA49.3 S4

3460x1400x2100

3400

XG-560GF

560/700

616/770

TWD1645GE

LSA49.3 M6

3460x1400x2100

3600

Perkins Engine and Marathon Alternator

Generator

Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-24GF

24/30

26/32.5

1103A-33G

GM-24-4

1500x730x1150

800

XG-30GF

30/37.5

33/41.25

1103A-33TG1

GM-30-4

1600x730x1250

950

XG-48GF

48/60

53/66.25

1103A-33TG2

MP-48-4

1750x750x1250

1030

XG-50GF

50/62.5

55/68.75

1104A-44TG1

MP-50-4

1950x750x1250

1050

XG-64GF

64/80

70/87.5

1104A-44TG2

MP-64-4

1950x750x1250

1100

XG-75GF

75/93.75

83/103.75

1104C-44TAG1

MP-75-4

1950x750x1250

1250

XG-100GF

100/125

110/137.5

1106A-70TG1

MP-104-4

2400x850x1400

1700

XG-120GF

120/150

132/165

1106A-70TAG2

MP-120-4

2400x850x1400

1780

XG-140GF

140/175

154/192.5

1106A-70TAG3

MP-140-4A

2400x850x1400

2200

XG-150GF

150/187.5

165/206.25

1106A-70TAG4

MP-160-4A

2400x850x1400

2250

XG-180GF

180/225

198/247.5

1506A-E88TAG2

MP-180-4A

2600x1050x1600

2380

XG-200GF

200/250

220/275

1506A-E88TAG3

MP-200-4A

2600x1050x1600

2400

XG-240GF

240/300

264/330

1506A-E88TAG5

MP-240-4A

2600x1050x1600

2500

XG-280GF

280/350

308/385

2206C-E13TAG2

MP-280-4A

3150x1200x2000

3450

XG-300GF

300/375

330/412.5

2206C-E13TAG3

MP-300-4A

3250x1200x2000

3500

XG-350GF

350/437.5

385/481.25

2506C-E15TAG1

MP-360-4A

3500x1200x2050

3600

XG-400GF

400/500

440/550

2506C-E15TAG2

MP-400-4

3500x1200x2050

3700

XG-480GF

480/576

528/660

2806A-E18TAG1A

MP-480-4

3500x1300x2100

4000

XG-500GF

500/625

550/687.5

2806A-E18TAG2

MP-500-4

3500x1300x2100

4600

XG-600GF

600/750

660/825

4006-23TAG2A

MX-600-4

4100x1750x2170

5300

XG-

640GF

640/800

704/880

4006-23TAG3A

MX-640-4

4100x1750x2170

5500

XG-720GF

720/900

792/990

4008TAG1A

MX-750-4

4700x2100x2250

7700

XG-800GF

800/1000

880/1100

4008TAG2A

MX-850-4

4700x2100x2250

7900

XG-1000GF

1000/1250

1100/1375

4012-46TWG2A

MX-1030-4

4900x1800x2500

10000

XG-1100GF

1100/1375

1210/1512.5

4012-46TWG3A

MX-1030-4

5000x2100x2550

10100

XG-1200GF

1200/1500

1320/1650

4012-46TAG2A

MX-1240-4

5000x2200x2550

10200

XG-1500GF

1500/1875

1650/2027

4016TAG1A

MX-1600-4

6850x2250x2850

13000

XG-1600GF

1600/2000

1760/2200

4016TAG2A

MX-1600-4

6850x2250x2850

13500

XG-1800GF

1800/2250

1980/2475

4016-61TRG3

MX-1800-4

6850x2250x2850

15000

Shangchai (SDEC) Engine and CSIC Siemens Alternator

Generator

 Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-50GF

50/62.5

55/68.75

SC4H95D2

1FC2 221-4

1900x750x1300

960

XG-75GF

75/93.75

83/103.75

SC4H115D2

1FC2 223-4

1950x900x1300

1050

XG-100GF

100/125

110/137.5

SC4H160D2

1FC2 281-4

2000x900x1300

1150

XG-120GF

120/150

132/165

SC4H180D2

1FC2 281-4

2100x900x1300

1300

XG-150GF

150/187.5

165/206.25

SC7H230D2

1FC2 282-4

2500x900x1630

1600

XG-150GF

150/187.5

165/206.25

SC7H250D2

1FC2 282-4

2500x900x1630

1600

XG-180GF

180/225

198/247.5

SC8D280D2

1FC2 283-4

2500x900x1630

1600

XG-180GF

180/225

198/247.5

SC13G280D2

1FC2 283-4

2500x900x1630

1600

XG-200GF

200/250

220/275

SC9D310D2

1FC2 283-4

3100x1020x1780

1950

XG-200GF

200/250

220/275

SC9D355D2

1FC2 283-4

3100x1020x1780

1950

XG-250GF

250/312.5

275/343.75

SC13G420D2

1FC2 284-4

3100x1020x1780

1950

XG-300GF

300/375

330/412.5

SC12E500D2

1FC2 351-4

3100x1020x1780

2700

XG-300GF

300/375

330/412.5

SC15G500D2

1FC2 351-4

3100x1020x1780

2700

XG-350GF

350/437.5

385/481.25

SC25G610D2

1FC2 353-4

3300x1400x1780

2850

XG-400GF

400/500

440/550

SC25G690D2

1FC2 354-4

3500x1400x1850

4000

XG-500GF

500/625

550/687.5

SC27G755D2

1FC2 355-4

3400x1400x1850

4500

XG-500GF

500/625

550/687.5

SC27G830D2

1FC2 355-4

4350x1750x2189

4460

XG-550GF

550/687.5

605/756.25

SC27G900D2

1FC2 451-4

4350x1750x2180

4650

XG-600GF

600/750

660/825

SC33W990D2

1FC2 451-4

4550x1750x2189

5860

XG-800GF

800/1000

8800/1100

SC33W1150

1FC2 453-4

4850x1850x2200

6500

Yuchai Engine and Starlight Alternator

Generator

 Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-40GF

40/50

44/55

YC4D75-D34

TFW2-40-4A

1850x760x1300

900

XG-50GF

50/62.5

55/68.75

YC4D90-D34

TFW2-50-4A

1950x760x1300

900

XG-60GF

60/75

66/82.5

YC4D105-D34

TFW2-60-4A

1950x760x1300

900

XG-75GF

75/93.75

83/103.75

YC6B135Z-D20

TFW2-75-4A

2200x900x1400

1100

XG-90GF

90/112.5

99/123.75

YC6B155L-D20

TFW2-90-4A

2350x950x1400

1200

XG-100GF

100/125

110/137.5

YC6B180L-D20

TFW2-100-4A

2400x950x1400

1300

XG-120GF

120/150

132/165

YC6B205L-D20

TFW2-120-4A

2400x950x1400

1700

XG-120GF

120/150

132/165

YC6A205-D30

TFW2-120-4A

2400x950x1400

1700

XG-140GF

140/175

154/192.5

YC6A230-D30

TFW2-140-4A

2500x1000x1500

1700

XG-150GF

150/187.5

165/206.25

YC6A245-D30

TFW2-150-4A

2600x1000x1500

1700

XG-200GF

200/250

220/275

YC6MK350-D30

TFW2-200-4A

2950x1200x1650

2600

XG-250GF

250/312.5

275/343.75

YC6MK420-D30

TFW2-250-4A

3000x1200x1655

3000

XG-280GF

280/350

308/385

YC6MK450-D30

TFW2-280-4A

3000x1200x1655

3000

XG-300GF

300/375

330/412.5

YC6MJ480L-D20

TFW2-300-4A

3100x1200x1655

3100

XG-320GF

320/400

352/440

YC6T550L-D21

TFW2-320-4A

3500x1300x1800

3200

XG-350GF

350/437.5

385/481.25

YC6T600L-D22

TFW2-350-4A

3800x1350x2070

4200

XG-400GF

400/500

440/550

YC6T660L-D20

TFW2-400-4A

3800x1350x2070

4200

XG-450GF

450/562.5

495/618.75

YC6TD780-D31

TFW2-450-4A

4500x1750x1950

5100

XG-500GF

500/625

550/687.5

YC6TD840-D31

TFW2-500-4A

4500x1750x1950

5600

XG-550GF

550/687.5

605/756.25

YC6TD900-D31

TFW2-550-4A

4500x1750x1950

5600

XG-600GF

600/750

660/825

YC6TD1000-D30

TFW2-600-4A

4500x1750x2100

6200

XG-650GF

650/812.5

715/893.75

YC6C1070-D31

TFW2-650-4A

4500x1750x2100

7000

XG-750GF

750/937.5

825/1031.25

YC6C1220-D31

TFW2-750-4A

4500x1750x2100

7200

XG-800GF

800/1000

880/1100

YC6C1320-D31

TFW2-800-4A

4800x1800x2500

7500

XG-1000GF

1000/1250

1100/1375

YC12VC1680-D31

TFW2-1000-4A

5400x2350x2700

15400

XG-1200GF

1200/1500

1320/1650

YC12VC2070-D31

TFW2-1200-4A

5400x2350x2700

16200

XG-1500GF

1500/1875

1650/2062.5

YC12VC2510-D31

TFW2-1500-4A

5900x2650x2950

17900

XG-1800GF

1800/2250

1980/2475

YC16VC3000-D31

TFW2-1800-4A

7400x2800x3250

22600

XG-2000GF

2000/2500

2200/2750

YC16VC3300-D31

TFW2-2000-4A

7600x2800x3250

23800

XG-2200GF

2200/2750

2420/3025

YC16VC3600-D31

TFW2-2200-4A

7800x2800x3250

24500

Deutz Engine and Shanghai KEPU Alternator

Generator

 Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-200GF

200/250

220/275

BF6M1015-G1A

TFW2-200-4

2720x1370x2130

2350

XG-250GF

250/312.5

275/343.75

BF6M1015C-G2A

TFW2-250-4

3000x1690x1950

2450

XG-300GF

300/375

330/412.5

BF6M1015C-G3A

TFW2-300-4

3200x1690x1950

2850

XG-350GF

350/437.5

385/481.25

BF8M1015C-G1A

TFW2-350-4

3200x1690x1950

3500

XG-400GF

400/500

440/550

BF8M1015C-G2

TFW2-400-4

3200x1690x2130

3700

XG-400GF

400/500

440/550

BF8M1015CP-G1A

TFW2-400-4

3200x1690x2130

3720

XG-450GF

450/562.5

495/618.75

BF8M1015CP-G2

TFW2-450-4

3400x1690x2130

3800

XG-500GF

500/625

550/687.5

BF8M1015CP-G3/4/5

TFW2-500-4

3400x1690x2130

4000

XG-600GF

600/750

660/825

HC12V132ZL-LAG1/2A

TFW2-600-4

3600x1750x2200

4500

Yuchai - MTU Engine and Shanghai KEPU Alternator

Generator

 Model

PRP

KW/KVA

EPS

KW/KVA

Engine Model

Alternator Model

Dimension (mm)

Weight (kg)

XG-1400GF

1400/1750

1540/1925

12V4000G23

TFW2-1400-4

6150x2400x2800

13000

XG-1500GF

1500/1875

1650/2062.5

12V4000G63

TFW2-1500-4

6150x2400x2800

14000

XG-1800GF

1800/2250

1980/2475

16V4000G23

TFW2-1800-4

6500x2700x2900

17000

XG-1900GF

1900/2375

2090/2612.5

16V4000G63

TFW2-1900-4

6550x2700x2950

17500

XG-2200GF

2200/2750

2420/3025

20V4000G23

TFW2-2200-4

7350x2700x3000

18000

XG-2400GF

2400/3000

2640/3300

20V4000G63

TFW2-2400-4

7400x3100x3300

18500

XG-2500GF

2500/3125

2750/3437.5

20V4000G63L

TFW2-2500-4

7400x3100x3320

19000

 

If you want to know about each brand of generator characteristics, please click standby generator

If you want to know about the latest price of generator, please send an inquiry to our mailbox: [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us