Home Products News Contact Us
Home > News > A 100KW Cummins Silent Diesel Generator Was Exported to French Polynesia

A 100KW Cummins Silent Diesel Generator Was Exported to French Polynesia

Sep. 19, 2024

Dingbo Power produced a prime power 100KW/125KVA diesel generator set powered by Dongfeng Cummins 6BT5.9-G2 engine in March, 2024. After being factory tested and certified, the product was exported to French Polynesia successfully. Thanks for the client’s trust and support.


Genset general information


ManufacturerGuangxi Dingbo Generator Set Manufacturing Co.,Ltd.
Genset modelDB-100GF
Prime power100kw/125kva
Standby power110kw/138kva
Rated voltage380/220V
Rated current190A
Power factor0.8lag
Frequency/Speed60Hz/1800rpm
Phase & Wire3 phase 4 wire
Type & Noise levelSilent type, 75dB at 7m
Diesel engineCummins 6BT5.9-G2
AlternatorOriginal Stamford UCI274D14
ControllerHGM6120NC+CMM366B-WIFI


This 100KW/125kva diesel generator set mainly consists of a Cummins 6BT5.9-G2 engine, an original Stamford UCI274D14 and a SmartGen HGM6120NC+CMM366B-WIFI controller. It produces reliable power with low emissions, making it suitable for various commercial and industrial applications. The sound attenuated enclosure is made of 2mm thick Galvanized steel, which not only reduces the noise level, but also protects the generator set from adverse weather, scratching, and corrosion.


A 100KW Cummins Silent Diesel Generator Was Exported to French Polynesia


The SmartGen HGM6120NC controller is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three remote (remote control, remote measure and remote communication). By adding mains AC monitoring and mains/generator automatic switching control (AMF), HGM6120NC is especially suitable for the automation system composed by mains and genset. CMM366B-WIFI Cloud Monitoring Communication Module connects to cloud server via wireless WIFI, one to one monitoring.


What are the safety precautions to follow when using a diesel generator?


Diesel generators are renowned for their reliability, high efficiency, durability and longevity. They can be used in different industries, such as disaster recovery, construction operations, data center backup power, mining operations, hospital backup for emergency, etc. However, there are certain risks that come with using diesel generators. Improper use and handling a diesel genset could be dangerous, which can even lead to injury or death. When you are the owner of a diesel generator, here are some safety tips that you need to know.


Place your generator in a proper location


It’s important to choose an appropriate location for your diesel generator. To minimize the risk of carbon monoxide poisoning, generators should be placed in the open, ideally outdoors or in dedicated generator rooms. Never use your generator inside a home, garage, basement, crawlspace or any partially enclosed area. Keep it away from doors, windows and vents that could allow carbon monoxide to come indoors. Installing your generator in a well-ventilated place can prevent he buildup of toxic exhaust gases like carbon monoxide. You can choose to install CO alarms to provide early warning of accumulating carbon monoxide.


Protect your generator from the elements


If your diesel generator set is installed outdoors, make sure that it has adequate protection from the harsh weather conditions. Canopy covers and steel enclosures offer protection against debris ingress and electrical failures during challenging weather conditions. You can choose a diesel generator with a weatherproof enclosure to keep it dry.


Don’t overload your generator


Before buying a diesel generator, calculate your power requirements and choose the right size generator. Make sure the generator can handle your electrical load of your business. Overloading your generator may cause overheating, inconsistent power generation and in some cases not start up at all.


Regular generator maintenance and inspections


A well-maintained diesel generator can provide you with reliable electricity in emergencies. It’s important to maintain and service your generator regularly to keep its optimal performance. Follow the manufacturer’s recommended maintenance schedule and conduct tasks such as refuelling, oil changes, and filter replacements regularly. Inspect the generator for any signs of wear, leaks, or corrosion. Routine inspections can identify and address issues promptly.


Dingbo Power is a professional diesel generator manufacturer in China with 18 years’ production experience. If you are looking for reliable power solutions and expert guidance, contact us today.


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us