There are many details to pay attention to in the use of diesel generator sets. Pay attention to the details in the use process, which is more conducive to protecting the diesel generator set. In this article, Dingbo power generation equipment will be introduced in detail for the reference of the majority of users.
Some friends think that the lower the cooling temperature, the better. In fact, this is not the case. As long as the coolant temperature does not exceed 95 degrees celsius, there will be no cavitation and the coolant will not be interrupted; on the contrary, if the coolant temperature is too low, right The harm of diesel engines is great. The reasons are as follows:
1. Because the lower the coolant temperature, the lower the temperature of the machine body, the viscosity of the oil in the lubrication system increases, and the running resistance of the parts increases, resulting in poor lubrication and increased wear between parts. For example, when the coolant temperature is 30 degrees celsius, compared with the coolant temperature of 80 to 90 degrees celsius, the wear of the cylinder liner, piston and piston ring will be 4 to 5 times that of the coolant temperature of 80 to 90 degrees Celsius.
2. The lower the coolant temperature, the worse the combustion condition in the diesel engine cylinder, the poor fuel atomization, the prolonged afterburning period, and the rough diesel engine operation will aggravate the damage of curved bearings, piston rings and other parts, reducing power and economy.
3. The lower the temperature of the coolant, the burned water vapor is likely to condense on the cylinder wall, causing metal corrosion.
4. If the fuel is incompletely burned, it will form gums, which will make the piston ring stuck in the piston ring groove, the valve will be stuck, and the pressure in the cylinder will decrease at the end of compression.
5. The fuel atomization is not good, the combustion is incomplete, the power is reduced, and the fuel consumption is increased. If the coolant temperature is 40 degrees Celsius, the fuel consumption of the diesel engine will be about 10% more than 80 degrees Celsius.
Therefore, the diesel engine coolant temperature is not as low as possible. Generally, it is better to control it between 80-95 degrees Celsius. As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences