In December, Dingbo company and Liujiang Huateng Real Estate Development Co., Ltd., a subsidiary of Hejing Taifu Group, successfully signed a 600KW and a 640KW Cummins diesel generator sets. These two units are used as emergency standby power for the first and second phase of the Yunxi Four Seasons Garden.
This is the second cooperation between our company and Hejing Taifu Group. Prior to this, our company has signed two sets of 520KW and 640KW Cummins diesel generators used in different projects of the Real Estate.
In this project cooperation, in addition to the supply of the diesel generator sets, Dingbo is also responsible for the installation and supporting environmental protection inspection and acceptance of the project, including: installation of diesel generating set and supporting environmental protection installation project, completion of equipment design and environmental design, manufacturing, testing, transportation, installation and commissioning, operation, acceptance and cooperation for environmental protection completion acceptance and other related services.
600KW & 640KW 50Hz 1500rpm 400V Cummins Diesel Generator Set Standard Features:
1. Radiator 50°C max
2. Fans are driven by belt, with safety guard
3. 24V charger alternator
4. 24V starter motor
5. Dry type air filter, fuel filter, oil filter
6. Shock pad
7. Muffler
8. Main circuit breaker, ATS is optional
9. IP23, Class H, 3 phase 4 wire
10. 24V free-maintenance battery, a set of maintenance tool, etc.
Reference Standards:
BS-5514 and DIN-6271 standards are based on ISO-3046.
Operation At Elevated Temperature And Altitude:
The engine speed is 1500r / min, the altitude is lower than 15000m (5000ft), and the ambient temperature is lower than 40°C (104°F).
The engine runs above the above conditions. When the altitude is higher than 1500m (5000ft), the power is reduced by 4% for every 300m (1000ft) increase; when the ambient temperature is higher than 40°C (104°F), the power is reduced by 2% for every 11°C increase (10°F increase, 1% decrease).
600KW Cummins Generator Basic Configuration:
Engine: Cummins / KTA38-GA
Prime power: 647 KW
Standby power: 711 KW
Type: 4 cycle, V type, 12 cylinder
Aspiration: Turbocharged
Bore and stroke: 159 x 159 mm
Displacement: 38 L
Compression ratio: 14.5:1
Fuel system: Cummins PT
Alternator: Stamford / LVI634B1
Controller: Deep Sea / 7320 MKII
640KW Cummins Generator Basic Configuration:
Engine: Cummins / KTA38-G2
Prime power: 664 KW
Standby power: 731 KW
Type: 4 cycle, V type, 12 cylinder
Aspiration: Turbocharged
Bore and stroke: 159 x 159 mm
Displacement: 38 L
Compression ratio: 14.5:1
Fuel system: Cummins PT
Alternator: Stamford / LVI634C1
Controller: Deep Sea / 7320 MKII
The two diesel generator sets use the Sino-US joint venture Cummins engine. It has the characteristics of small size, light weight, low fuel consumption, low noise, high output power, convenient supply and maintenance of parts, and its reliable stability, economy, and power performance, durability and environmental safety are welcomed by users at home and abroad.
Dingbo is one of leading manufacturers of diesel generator sets in China. With strong research and development strength, modern production technology, professional manufacturing technology, advanced testing equipment, perfect quality management system, we can provide various types of automatic diesel generator sets for customers to choose, but also to meet users’ demand of different voltage and frequency.
As the largest Cummins diesel genset OEM cooperative manufacturer in China, we can provide 20 KW to 2400 KW new diesel generators powered by Cummins engine. If you have a plan to purchase Cummins generator, please send an inquiry to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences