Home Products News Contact Us
Home > News > Dingbo Power Exported A 256kw Cummins Diesel Generator to the Middle East

Dingbo Power Exported A 256kw Cummins Diesel Generator to the Middle East

Jan. 15, 2025

In July, 2023, a client from the Middle East placed an order for a 320kw silent diesel generator. The genset mainly consists of a Cummins engine, a Shanghai Stamford alternator and a SmartGen controller. After completing production, Dinbo Power delivered the product to the client successfully. Thanks for the client’s trust and support.


Technical data of 256kw genset


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-256GF

Type: Silent type

Standby power: 256kw

Rated voltage: 400/230V

Rated Current: 461A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins 6LTAA9.5-G3

Alternator: Shanghai Stamford GR314ES

Controller: SmartGen HGM6110


Dingbo Power Exported A 256kw Cummins Diesel Generator to the Middle East


This genset is powered by DCEC Cummins 6LTAA9.5-G3 engine, which has a mechanical fuel system designed to deliver robust performance in the most extreme conditions. It also has electronic governor controls for superior engine speed stability and transient response. The cylinder head has 24-valves and bigger flow injector design which provides one of the highest power-to-weight ratios in its class. At the same time, the 6LTAA9.5 engine delivers better fuel economy and less smoke emission than similar engines.


General engine data


Manufacturer: Dongfeng Cummins Engine Co.,Ltd

Model: 6LTAA9.5-G3

Prime/Standby power: 250/280kW

Frequency & Speed: 50Hz,1500rpm

Cylinders no. & Type: 6 cylinders, Inline, 4 stroke, diesel engine, water-cooled

Aspiration: Turbocharged & Charge Air Cooled

Bore*stroke: 116*148mm

Displacement: 9.5L

Governor: Electronic speed governor

Starter motor voltage: 24V DC

Fuel System: Bosch direct injection

Lube oil capacity: 32.4L

Coolant capacity: 55.5L


Features of Cummins 6LTAA9.5engine


Fuel system - Bosch P7100 type mechanical fuel injection pumps have high injection pressure, optimize engine performance and establish an unrivalled reputation for reliability.


Electronic governor control unit - Strengthening electronic governor control unit to optimize engine speed stability, transient response and reliability.


Cummins Holset HE400 and HE500 Nonwastegate turbocharger – Cummins optimized turbocharger delivers increased power, fuel economy, low smoke and lower noise levels.


Electronic fuel shut off valve – Robust design for safety for mechanical fuel system engine.


Integrated block design - Integrated fluid circuits replace hoses and eliminate potential leaks.


24-valve cylinder head - Four valves per cylinder for increased power with faster response and improved fuel economy.


Coolpac integrated design - Products are supplied complete with cooling package and air cleaner kit for a complete power package. Each component has been specifically developed and rigorously tested for Cummins G-Drive standards, ensuring high performance, durability and reliability.


Service and support - G-Drive products are backed by an uncompromising level of technical support and after sales service, delivered through a world class global service network.


This genset will be used as an emergency diesel generator (EDG), which supplies electrical power to a facility during a blackout (loss of power). When buying a diesel generator, it’s necessary to have a basic understanding of generator ratings.


Emergency Standby Power (ESP) is applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Limited-Time Running Power (LTP) is applicable for supplying power to a constant electrical load for limited hours. Prime Power (PRP) is applicable for supplying power to varying electrical load for unlimited hours. Base Load (Continuous) Power (COP) is applicable for supplying power continuously to a constant electrical load for unlimited hours.


Looking for a diesel generator for your business? Contact us today! Dingbo Power is here to help - with various types of diesel generators you can count on. Get prepared for the unexpected today.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us