On June 8, 2020, we sold 4 units diesel generator set powered by Cummins engine. They are 2 units 1000kw, 1 unit 150kw and 1 unit 120kw. The 4 units are powered for motorway project. The total investment of the motorway project is 36.84 billion yuan, with a total length of 162.3 km and a design speed of 100 km/h. The buyer is very satisfied with our product and service, so they purchased genset from us again, this is the fourth cooperation.
Our Cummins diesel generator set is the most popular among Perkins, Volvo, Deutz, Yuchai, Shangchai, Ricardo etc, because of low fuel consumption, stable performance and high quality tec.
Below are the technical specifications of 1000kw, 150kw and 120kw Cummins diesel generators.
1. 1000KW Cummins diesel genset
Prime/standby: 1000kw/1100kw
Genset type: open type
Rated current: 1800A
Rated voltage: 230/400V
Speed/frequency: 1500rpm/50Hz
Power factor: 0.8lag
Diesel engine: Cummins/ QSK38-G5
Alternator: Shanghai Kepu/ TFW2-1000
Controller: SmartGen HGM6110
Overall size: 4800x 2080x2350mm
Net weight: 9800kg
2. 150kw Cummins power diesel generator
Prime/standby: 150kw/165kw
Genset type: open type
Rated current: 270A
Rated voltage: 230/400V
Speed/frequency: 1500rpm/50Hz
Power factor: 0.8lag
Diesel engine: Cummins/ QSB6.7-G4
Alternator: Shanghai Kepu/ TFW2-150
Controller: SmartGen HGM6110
Overall size: 2400x 850x1500mm
Net weight: 1700kg
3. 120KW Cummins electric generator
Prime/standby: 120kw/132kw
Genset type: open type
Rated current: 216A
Rated voltage: 230/400V
Speed/frequency: 1500rpm/50Hz
Power factor: 0.8lag
Diesel engine: Cummins/ 6BTAA5.9-G12
Alternator: Shanghai Kepu/ TFW2-120
Controller: SmartGen HGM6110
Overall size: 2300x 830x1400mm
Net weight: 1300kg
Accessories of about genset are included auto start/stop monitoring system, silencer, battery charger, 24V DC battery, rubber shock pad, factory test, operation manual, maintenance and repair manual etc. For 1000kw Cummins genset, also includes one set of maintenance tool kit.
Advantages of Dingbo diesel generators with Cummins engine
1. Low oil consumption, stable and reliable performance, simple and convenient maintenance, long service life.
2. Advanced technologies for fuel system, control system, air intake treatment, filtration system, exhaust gas treatment system and power system. So its performance is very good.
3. The main design features of Cummins engine are solid and durable cylinder body, low vibration and noise. In-line six cylinder four stroke, stable operation and high efficiency; replacement of wet cylinder sleeve, two cylinders and one cover, four valves per cylinder, sufficient air intake, forced water cooling, small thermal radiation and excellent performance.
4. Excellent quality, low noise, small volume, strong output power, reliable performance.
5. Global warranty.
We are a manufacturer of electric generators in China, our Cummins genset power range is from 20kw to 2000kw, if you have purchase plan, welcome to contact us by email [email protected] or call us +8613481024441.
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences