Recently, Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. signed a manufacturing agreement on two sets of 500KW diesel generators, which are powered by Chongqing Cummins engine KTAA19-G6A, and reached a cooperative relationship.
It is understood that Dingbo Power Group is responsible for the whole process from production to installation of the 500KW Cummins generator set. The signing of the cooperation between two sets of 500KW Chongqing Cummins generator sets marks another small step for Dingbo Power Group in the production and construction of diesel generator sets. In the future, under the principle of win-win cooperation, Dingbo Power Group will be responsible for maintaining two 500KW Chongqing Cummins generator sets and helping the customer manage the diesel genset.
Here is main technical datasheet of 500kW/625kVA Cummins diesel generator set:
Specifications | |
Supplier | Guangxi Dingbo Generator Set Manufacturing Co.,Ltd. |
Model | XG-500GF |
Prime Power | 500KW/625KVA |
Standby Power | 550KW/687.5KVA |
Rated voltage | 400V |
Rated current | 900A |
Power factor | 0.8LAG |
Frequency | 1500RPM |
Speed | 50Hz |
Engine model | Chongqing Cummins KTAA19-G6A |
Prime power of engine | N/A |
Standby power of engine | 610KW |
Number of cylinders | 6, inline |
Bore and stroke | 159 x 159 mm |
Displacement | 19 Liters |
Aspiration | Turbocharged , Air-to-air Cooled |
Cycle | 4 stroke |
Combustion system | Direct injection, Cummins PT |
Compression ratio | 13.9:1 |
Rotation | Anti-clockwise, viewed from flywheel end |
Total lubricating capacity | 84.4 litres |
Cooling system | Water-cooled |
Total coolant capacity | 112 litres |
Fuel consumption at 1500 rpm | |
Standby power(maximum) | 216g/kw.h |
Alternator | Cummins Stamford HCI544FS1 |
Prime power of alternator | 500KW |
Standby power of alternator | 550KW |
Insulation class | H |
Winding pitch | 2 |
Wingding leads | 12 |
Protection | IP23 |
Excitation system | Brushless, self-excited |
AVR type | AS440 |
Voltage regulation (*) | ±1% |
Short-circuit current | 300% (3 IN) : 10 |
Total Harmonic Distortion THD (**) in no-load | < 4% |
Waveform: NEMA = TIF (**) | < 50 |
Waveform: I.E.C. = THF (**) | < 2% |
Overspeed | 2250 R.P.M |
Altitude | ≤1000M |
Air flow | 2.5 m3/s (50 Hz) - 2.8 m3/s (60 Hz) |
Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in Cummins generators or any question on generator, welcome to send email to [email protected].