Home Products News Contact Us
Home > News > How Can Volvo generators Save Fuel?

How Can Volvo generators Save Fuel?

Aug. 05, 2023

Maintain the best oil supply angle of Volvo generators to ensure that the machine does not leak oil: When excessive oil consumption is found, first check whether there are leaks at the connections between the body and the gear chamber cover, the large plate on the side of the wheel, the rear cover, and the cover. Oil phenomenon. In case of oil leakage, pay attention to observe whether the gaskets at each connection part are intact, and replace the damaged gaskets. If the gasket is intact, check whether the connecting screws of each part are loose.

 

For loose bolts, use a wrench to reach the specified torque. If the above parts are basically normal and the oil leakage is at the position of the frame, the oil shell should be inspected. The main inspection part is the front end of the oil shell side on the same side as the traveling wheel. Mostly because of the loosening of the screw on the base, the traveling wheel is pulled by the triangle belt. Long-term friction with the frame angle iron protecting the oil shell will cause the oil shell to grind through to form a gap and cause oil leakage.


Perkins generator 100kw 2250kva Cummins Diesel Generator Set


Purify the oil before use, pay attention to the daily maintenance of the engine: normal wear caused by long-term use of the engine, or abnormal wear caused by improper maintenance, will cause the cylinder liner of the diesel generator to form longitudinal pull marks, cylinder diameter, and piston side clearance If the specified value is exceeded, the supporting force of the piston ring will be reduced correspondingly, and the phenomenon of oil scraping will appear.


Because the internal support twisting spring in the oil ring is disconnected at the opening position of the oil ring, the oil is not clean and participates in the combustion, causing severe oil consumption symptoms, manifested by the difficulty of starting the diesel engine, and the exhaust pipe has obvious blue smoke. The respirator is spraying badly.


In addition, the piston should be on the upward side. The combustion chamber is turned upside down during assembly. Although it will not affect the start of the diesel engine, the oil loss will be quite serious, with daily fuel consumption of about 0.5 kg. Although it is rare that the valve guide will burn the oil of Volvo generator when it is severely worn, it is also a reason not to be underestimated according to relevant information.


Increase the temperature of the Volvo generator cooling water and operate the Volvo generator more reasonably: try to make the Volvo generator's fuel burn fully, that is, the Volvo generator uses 80% of the Volvo generator's output power. Control the fuel injection pump to ensure that the fuel supply of the fuel injection pump is not too large. Control the oil in the governor to prevent the increase in oil supply, otherwise it will all cause the Volvo generator to "speed".


In addition, we must pay great attention to the smoking phenomenon of Volvo generators. If the Volvo generator emits smoke or black smoke, these indicate that the Volvo generator is working abnormally and must be checked and handled in time. Only by keeping the Volvo generator in the best working condition can the fuel-saving goal of the Volvo generator be achieved, thereby reducing the cost of use and reducing environmental pollution.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us