Home Products News Contact Us
Home > News > Nanning LM Machinery Company Placed an Order for A 250KW Cummins Diesel Generator

Nanning LM Machinery Company Placed an Order for A 250KW Cummins Diesel Generator

Nov. 14, 2024

On October 29, 2024, Nanning LM Machinery Equipment Co., LTD placed an order of a 250kw Cummins silent diesel generator from Dingbo Power. The genset mainly consists of a Dongfeng Cummins 6LTAA9.5-G1 engine and a Shanghai Stamford GR3114DX alternator, which ensures its excellent performance and longevity.

 

Below are the technical data of the genset:


Genset Model:DB-250GF
ManufacturerGuangxi Dingbo Generator Set Manufacturing Co.,Ltd.
StandardsGeneral technical condition for power frequency diesel-generating sets
Prime power(KW)250Steady voltage governing rate≤±0.5% 
Standby power(KW)275Transient voltage governing rate≤+20~-15%
Rated frequency(Hz)50Voltage steady time≤1S
Rated Voltage (V)415/240VVoltage volatility≤±0.25%
Rated Current(A)435Steady frequency governing rate≤±0.5% 
Genset net weight(kg)3100Transient frequency governing rate≤±7% 
Genset dimensions(mm)Length*Width*Height3600*1400*2000Frequency steady time≤1S


Nanning LM Machinery Company Placed an Order for A 250KW Cummins Diesel Generator


Engine technical specifications


ManufacturerDongfeng Cummins Engine Co.,Ltd
Model6LTAA9.5-G1
Engine output-prime290kW
Engine output-standby320kW
Frequency:50Hz
Speed:1500rpm
Cylinders no. & Type:6 cylinders, Inline, 4 stroke, diesel engine, water-cooled
Aspiration:Turbocharged and Charge Air Cooled
Bore*stroke116*148mm
Displacement9.5L
Compression Ratio16.6:1
GovernorElectronic speed governor
Starter motor voltage:24V DC
Type Injection System:direct injection
Maximum Oil Temperature121℃
Minimum Required Lube System Capacity - Sump plus Filters28.1L
Cooling wayWater Radiator & fan
Coolant Capacity55.5L


After a number of rigorous verification and testing, this diesel generator set has demonstrated its exceptional stability, durability and reliability. Especially in terms of fuel efficiency, the genset can effectively reduce the fuel consumption and bring considerable economic benefits to users by optimizing the design. In addition, the unit has superior cold start capability and low noise level. It can operate smoothly in cold environmental conditions and be used in places with strict noise requirements.

 

It is worth mentioning that the cooperation between LM Machinery company and our company has a long history and a deep foundation of trust. The most recent collaboration took place in July 2023. LM Machinery purchased a 400KW Dongfeng Cummins silent generator set from our company at that time. We are very grateful to LM Machinery for its support and trust in Dingbo Power and we look forward to the opportunities to cooperate again in the future to make great achievement together.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us