Home Products News Contact Us
Home > News > Precautions for Purchasing Mine Diesel Generators

Precautions for Purchasing Mine Diesel Generators

Aug. 05, 2023

Diesel generators for mines have higher power requirements than conventional places. So what issues should we pay attention to when choosing mine diesel generators? Diesel generator manufacturers give you a brief introduction.


Understand the electrical equipment of your own mine: What you need to understand is the type of electrical equipment and the power of the main motor, the starting method, the starting law and other factors. It is necessary to specifically explain here that the power of a single motor is very large for the equipment of the mine. Therefore, it is necessary to choose a more excellent starting method, otherwise the investment budget for using diesel generators will be doubled.


On the other hand, large motors used in mines have a common feature, that is, the problem of large starting load but small load after operation. If the calculation is not good or the starting method selected is not good, it will waste a lot of manpower, material resources and other costs. Therefore, you can integrate your own investment budget and communicate with equipment manufacturers and diesel generator manufacturers to select and appropriate solutions. After selecting the starting mode, calculate the starting current (during the worst working condition) and operating current of all equipment, and finally calculate how much power diesel generators need to be configured.

Perkins generator 100kw 2250kva Cummins Diesel Generator Set


Consideration of environmental factors: Everyone in the mine knows that the operating environment is very harsh, and even some places are located at high altitudes. Like humans, the power carrying capacity of diesel generators decreases with the increase in altitude, so special attention is needed. It is necessary to take this factor into consideration, otherwise it will cause the disadvantages of the purchased power and the actual operating power.


Purchasing according to applicable functions: For diesel generator manufacturers specializing in mines, there will be some special configurations, such as heavy-duty filters to prevent wind and sand, low-temperature starting devices, and early warning devices that regularly remind the unit to maintain. Most of the diesel generators in mines are operated in parallel. The major fault signs of diesel generators cannot be observed with sound or naked eyes (such as abnormal noise, jitter, minor three leaks, etc.). If you have an alarm device, you can effectively monitor the crankcase. Pressure can greatly avoid the occurrence of some major engine failures (such as the deadly cylinder pull and pull phenomenon for diesel generators).


Determine the number of units according to the actual situation: For the main mine diesel generators, one more set of units must be reserved for long-term backup. This seems to be a large investment in the short term, but as long as it is equipment, there will eventually be In the event of a failure, it must be necessary to have one more backup unit in the long run. Mine diesel generators need to routinely purchase and inventory the daily wearing parts and parts that are prone to failure, so that spare parts can be provided for emergency when a failure occurs.


Tips: Most diesel generators used in mines are far away from the main urban area. Therefore, the technical level of the operators of diesel generators must be high. The improvement of this type of technology can be carried out with some manufacturers with large-scale training and technical support. Cooperation, mine diesel generators are an important means of production for mines, so it is especially important to have high-level technicians!


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us