In the standby stage, the standby Volvo diesel generator set is in a standby state, but because the standby Volvo diesel generator set is a backup power supply, the integrity and safety of the starting system are very important during emergency start. Therefore, it is necessary to strengthen the backup care and maintenance of Volvo diesel generator sets.
The starting of the Volvo diesel generator set relies on the battery, so it is necessary to strengthen the maintenance and maintenance of the battery of the Volvo diesel generator set. When the battery is in the standby state, it needs to reach the rated voltage. In the daily maintenance management, it is necessary to strengthen the monitoring of the voltage of the Volvo diesel generator set battery.
When charging it, when the voltage of the battery reaches the rated voltage, the charging will be stopped, and the battery will be charged automatically when the rated voltage is low. It is necessary to monitor the voltage of the battery and set up automatic charging equipment.
In the process of battery maintenance of Volvo diesel generator set, it is necessary to pay attention to the internal components of the battery. If the performance of the electrolyte inside the battery decreases, it needs to be replenished in time, and the terminals corroded by the electrolyte should also be replaced in time.
Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences