Before using the silent diesel generator, the master should check the oil, coolant, cable, circuit breaker, control system and other items. If a problem occurs in a certain item, it will affect the safe operation of the silent diesel generator. Therefore, the silent diesel generator It is necessary to check before use. For example, the amount of oil will directly cause the silent diesel generator to leave a hidden trouble. If the amount of oil is insufficient, the load operation will increase the friction between the engine parts, and the failure will occur over time.
Lubrication: As long as the silent diesel generator is in operation, the internal parts will produce friction. The faster the speed, the more intense the friction. For example, the temperature of the piston can reach more than 200 degrees Celsius. If there is no oil, diesel power generation silent diesel generator, the temperature will be high enough to burn the entire engine. The first function of engine oil is to use the oil film to cover the metal surface inside the engine to reduce the frictional resistance between metals.
Heat dissipation function: In addition to the cooling system, the engine oil is also an important role for the heat dissipation of the silent diesel generator itself, because the oil will flow through the interior of the engine and can take away the heat generated by the friction of the parts, which is far away from the cooling system. The piston part can also get some cooling effect through oil.
Cleaning effect: The carbon generated by the engine's long-term operation and the residues left over from combustion will adhere to the inside of the engine. If not properly treated, it will affect the function of the engine, especially these things accumulate on the piston ring and the intake and exhaust. Carbon deposits or sticky substances will be generated in doors and other places, causing knocks, frustrations, and increased fuel consumption. These phenomena are the enemy of engines. The oil itself has a clean and dispersing effect, which can prevent these carbon and residue from accumulating inside the engine, allowing them to form small particles, which are suspended in the oil.
Anti-corrosion and anti-rust effect: After a period of driving of soundproof generator, various corrosive oxides will naturally form in the oil, especially the strong acids in these corrosive substances, which are more likely to affect the internal parts of the engine. Causes erosion; At the same time, most of the moisture generated by combustion will be taken away with the exhaust gas, but a little moisture will remain, so it will also damage the engine. Therefore, the additives in the engine oil have anti-corrosion and anti-rust functions to protect quiet generator from these harmful substances.
Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences