In late December 2024, a valued client in Nepal ordered 3 sets of Cummins silent diesel generators from Dingbo Power. This order, consisting of one 150kW and two 200kW generator sets, underscores the growing international recognition of Dingbo Power as a trusted provider of reliable power solutions.
The Nepalese customer selected our Cummins-powered generator sets, renowned for their durability and efficiency. Each unit is equipped with a Stamford alternator and a Deep Sea controller, ensuring stable and intelligent power management.
Our silent generator sets are built with 2mm thick galvanized steel for enhanced durability and corrosion resistance. To meet the customer’s branding requirements, we customized the canopies by spraying their logo on the exterior. For ease of transportation and installation, the silent enclosures are designed with forklift slots at the bottom for smooth ground handling and lifting lugs on top for secure crane-assisted movements.
Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.
Genset model: DB-150GF
Type: Silent type
Prime Power: 150KW/188KVA
Standby power: 165KW/206KVA
Rated voltage: 400/230V
Rated Current: 270A
Speed/frequency: 1500rpm/50Hz
Power factor: 0.8lag
Phase & Wire:3 Phase 4 Wire
Diesel engine: Cummins QSL8.9-G2
Alternator: Original Stamford UCI274H14
Controller: Deep Sea DSE7320
Base bottom fuel tank: 8 hours operation
Noise level: 72dBA at 1 meter
Capacity of ATS: 300A
Manufacturer: | Dongfeng Cummins Engine Co.,Ltd |
Engine model | QSL8.9-G2 |
Prime power: | 206KW |
Standby power: | 226KW |
Frequency/Speed: | 50Hz/1500RPM |
Cylinders no. & Type: | 6 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan |
Aspiration: | Turbocharged ,Charged Air Cooled |
Displacement: | 8.9L |
Compression ratio | 17.73:1 |
Governor | Electronic speed control |
Bore x Stroke(mm): | 116.5 x 144.5mm |
Start mode: | Electric start |
Starter motor: | 24V DC, negative ground |
Fuel System: | Direct injection |
Total Oil System Capacity | 28.1L |
Cooling way | Water-cooled |
Engine Coolant Capacity | 11.1L |
Standard Thermostat (Modulating) Range | 82~95℃ |
Maximum Oil Temperature | 121℃ |
Fuel consumption-standby power@100% | 59L/h |
Fuel consumption-prime power@25% / 50% / 75% / 100% | 16L/h / 31L/h / 45L/h / 55L/h |
Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.
Genset model: DB-200GF
Type: Silent type
Prime Power: 200KW/250KVA
Standby power: 220KW/275KVA
Rated voltage: 400/230V
Rated Current: 360A
Speed/frequency: 1500rpm/50Hz
Power factor: 0.8lag
Phase & Wire:3 Phase 4 Wire
Diesel engine: Cummins 6LTAA8.9-G2
Alternator: Original Stamford UCDI274K14
Controller: Deep Sea DSE8610
Base bottom fuel tank: 8 hours operation
Noise level: 75dBA at 1 meter
Capacity of ATS: 400A
Manufacturer: | Dongfeng Cummins Engine Co.,Ltd |
Engine model | 6LTAA8.9-G2 |
Prime power: | 220KW |
Standby power: | 240KW |
Frequency/Speed: | 50Hz/1500RPM |
Cylinders no. & Type: | 6 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan |
Aspiration: | Turbocharged ,Charged Air Cooled |
Displacement: | 8.9L |
Compression ratio | 16.6:1 |
Governor | Electronic speed control |
Bore x Stroke(mm): | 114 x 145mm |
Start mode: | Electric start |
Starter motor: | 24V DC, negative ground |
Fuel System: | Direct injection |
Minimum Required Lube Oil System Capacity | 27.6L |
Cooling way | Water-cooled |
Engine Coolant Capacity | 11.2L |
Standard Thermostat (Modulating) Range | 82~93℃ |
Maximum Oil Temperature | 121℃ |
Fuel consumption-standby power | (100%):58L/h |
Fuel consumption-prime power @25% / 50% / 75% / 100% | 15L/h / 27L/h / 39L/h / 53L/h |
The 150kW diesel generator features a noise level of 72dB at 1 meter, ideal for environments requiring low disturbance. It comes with an 8-hour base fuel tank for extended operation. With a slightly higher noise level of 75dB at 1 meter, the 200kW silent gensets include a 12-hour base fuel tank, making them perfect for longer operational demands.
We extend our gratitude to our Nepalese partner for their trust and look forward to further collaborations. At Dingbo Power, we continue to empower industries worldwide with efficient, quiet, and dependable generator solutions.
For inquiries about our silent generator sets or other power products, feel free to contact us today!
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences