Due to the low external environment temperature of the diesel generator set, when the water temperature drops after 15 minutes of shutdown, the cooling water should be discharged, but not immediately. Otherwise, due to the large temperature difference between the body and the external environment, some components of the diesel generator set engine will deform, which will affect the performance of the diesel generator set engine (such as cylinder head deformation).
When draining water, it is not advisable to turn on the drain switch to ensure that everything is in order. It is also important to observe the specific condition of the water flow to see if it is smooth and if there are any signs of water flow decreasing or slowing down. If these situations occur, it indicates that the cooling water contains impurities that hinder the normal flow of water. At this time, it is advisable to remove the drain switch and allow the cooling water to flow directly out of the body.
If the water flow is still not smooth, then hard and slender steel objects such as iron wires should be used to clear the diesel generator set until the water flow is smooth. After the cooling water stops flowing out, shake the diesel generator set for a few more turns. At this time, the remaining and difficult to flow cooling water will flow out completely due to the vibration of the diesel engine, which can prevent the water blockage on the cylinder head from freezing and falling, and the cooling water will flow into the oil shell in the future.
At the same time, it should also be noted that if the drain switch is not removed, after the drain is completed, the drain switch should be in the open state to prevent unnecessary damage to the corresponding components of the diesel engine of the diesel generator set caused by the temporary inability of the remaining cooling water to flow out due to various reasons.
Founded in 1974, Dingbo Power Generation Equipment Co., Ltd. is a professional manufacturer of diesel engines, generators and generator sets, and one of the earliest manufacturers of diesel engines, generators and generator sets in China. Since 1992, the company has been a qualified generator set manufacturer inspected by the National Internal Combustion Engine Generator Set Quality Supervision and Inspection Center. Over the years, the company has carried out extensive cooperation with Shanghai Diesel, Weichai, Sweden Volvo, Sino US joint venture Chongqing Cummins, American Qianglu and other companies, and has become a (OEM) supporting factory and technical center. It has 64 sales service departments nationwide, providing users with design, supply, commissioning and maintenance services at any time. Dingbo quality is worth depending on. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.
Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap
Update cookies preferences